Original Research Paper Anaesthesiology

COMPARISON OF CLONIDINE, DEXMEDETOMIDINE & FENTANYL FOR ATTENUATION OF HEMODYNAMIC RESPONSE TO LARYNGOSCOPY & ENDOTRACHEAL INTUBATION IN VALVULAR HEART SURGERY

Indu Verma Jitendra Kumar C.K. Vyas Reema Meena Anjum Saiyed

Abstract

<p> <span style="text–align: justify;">There have been a lot of studies comparing the hemodynamic response during laryngoscopy & tracheal intubation in patients not having cardiac pathology. This study was done to compare the response of clonidine, fentanyl & dexmedetomidine hemodynamically in patients of valvular heart disease undergoing valvular replacement.</span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal"><o:p></o:p></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal"><o:p> </o:p></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal"><b>METHOD<o:p></o:p></b></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal"> This is a hospital based randomized controlled double blind interventional study. Total 93 patients were selected & divided in 3 groups in which 31 patients were included in each group. The patients in group F were given I.V Fentany l, in group C were given I.V Clonidine & in group D were given Dexmedetomidine. Anaesthesia was maintained with Isoflurane, fentanly & vecuronium bromide.<o:p></o:p></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal"><o:p> </o:p></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal"><b>RESULTS<o:p></o:p></b></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal"> In group D the mean change in Systolic B.P was higher as compared to group C&F 10 minutes after infusion. There was a statistically significant decrease in Diastolic B.P after 10 minutes of infusion in both group C & D. There was also a statistically significant decrease in Mean arterial pressure (MAP)10 minutes after infusion in group C &D from the baseline. Comparison of mean change in MAP between the 3 groups showed that the mean difference was significantly less in group F as compared to group C & D 10 minutes after & 7–10 minutes after intubation. There was also a statistically significant decrease in pulse rate 10 minutes after infusion in group C & group D as compared to baseline.<o:p></o:p></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal"><o:p> </o:p></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal"><b>CONCLUSION<o:p></o:p></b></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal"> Clonidine & Dexmedetomidine showed a better response to attenuate the pulse rate & B.P which is statistically significant and can be recommended pre–operatively 10 minutes before to attenuate the sympathetic response to laryngoscopy & intubation.<o:p></o:p></p>
<p class="MsoNormal" align="center" style="margin–bottom:0in;margin–bottom:.0001pt;
text–align:center;line–height:150%"><span style="line–height: 150%;"> </span></p>