Original Research Paper Ophthalmology

Comparative analysis of central corneal thickness measurements using Ultrasound Pachymetry and Galilei Dual Scheimpflug analyzer.

Dr.GunjanVerma Dr.Shwetambari Singh Dr.Dipali Satani

Abstract

<p> <b style="text–align: justify;"><span style="font–family: Cambria, serif;">Purpose</span></b><span style="text–align: justify; font–family: Cambria, serif;">: To assess comparability and interchangeability of central corneal thickness measurement by Ultrasound(US) Pachymetry and Galilei dual Scheimpflug Analyzer and to assess interobserver variation of Galilei dual Scheimpflug Analyser.</span></p>
<p class="MsoNormal" style="text–align:justify"><b><span style="font–family: Cambria, serif;">Materials and methods: </span></b><span style="font–family: Cambria, serif;">In 130 healthy eyes of 65 subjects central corneal thickness (CCT) measurements were take with Galilei Dual Scheimpflug Analyser followed by ultrasound pachymetry. All the readings were taken by single operator. </span><span style="font–family: Cambria, serif;">For calculating interobserver reproducibility, measurements were taken on Galilei Dual Scheimpflug Analyser by two observers at 5 mintues interval </span><span style="font–family: Cambria, serif;">in another 50 healthy eyes.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify"><b><span style="font–family: Cambria, serif;">Results: </span></b><span style="font–family: Cambria, serif;">The mean corneal pachymetry (central corneal thickness) measured with US pachy was 530.99 ±26.32 micron (skewness 0.563kurtosis 0.530) and that measured by Galilei was 530.35±26.42 (skewness 0.538, kurtosis 0.84). </span><span style="font–family: Cambria, serif;">There was no statistically significant difference between the CCT readings taken by Galilei and US pachy (<i>P</i> < 0.001). Interobserver reproducibility for the Galilei was 0.551%.</span><span style="font–family: Cambria, serif;"><o:p></o:p></span></p>
<p><b><span style="font–size: 11pt; line–height: 115%; font–family: Cambria, serif;">Conclusion</span></b><span style="font–size: 11pt; line–height: 115%; font–family: Cambria, serif;">: </span><span lang="EN–IN" style="font–size: 11pt; line–height: 115%; font–family: Cambria, serif;">Pachymetry readings taken with Ultrasound pachymetry and Galilei have good concordance and high reproducibility, </span><span style="font–size: 11pt; line–height: 115%; font–family: Cambria, serif;">and can be delegated to non medical but trained person</span></p>

Keywords: corneal pachymetry, ultrasound pachymetry, galilei dual scheimpflug analyser