Original Research Paper Anesthesiology

COMPARATIVE STUDY OF CLINICAL PERFORMANCE OF IGEL WITH PROSEAL LARYNGEAL MASK AIRWAY IN ADULT PATIENTS FOR ELECTIVE SURGERIES

PRIYANKA RATHI NILESH JAWE PRAKASH DHUMAL PADMANABHA D.V

Abstract

<p> <b style="text–align: justify;"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">AIM: </span></b><span style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">To compare the I–GEL and Proseal LMA(PLMA) in elective surgeries with regard to Ease and success rate of insertion,, time of insertion Airway sealing pressure, Ease of gastric tube placement and associated complication.</span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;text–justify:inter–ideograph;line–height:200%;mso–layout–grid–align:
none;text–autospace:none"><b><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Materials</span></b><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">: In a prospective randomized study, 60 adult patients of ASA I–II of either gender between 18 and 60 years presenting for a short surgical procedure under general anesthesia using either i–gel or PLMA. An experienced anesthesiologist inserted appropriate sized i–gel or PLMA in patients using standard insertion technique and assessed the intraoperative findings of the study regarding time taken for respective device insertion, effective seal, ease of gastric tube insertion and complications were done.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:inter–ideograph;
line–height:200%"><b><span style="font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif; background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial;">RESULTS: </span></b><span style="font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif; background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial;">There were no significant differences in demographic and hemodynamic data. Ease of insertion and success rate were comparable no significant difference in both devices (<em>P</em><span class="apple–converted–space"> </span>> 0.05) (Chi–square test). The mean time for insertion was more with PLMA (25.23 + 5.463 sec) than with IGEL (16.80 + 3.336 sec) (<em>P</em><span class="apple–converted–space"> </span>< 0.05). Although the airway sealing pressure was significantly higher with PLMA (28.93 + 2.212 cm of H<sub>2</sub>O), the airway sealing pressure of IGEL (26.07 + 3.073 cm of H<sub>2</sub>O) was very well within normal limit (Student‘s<span class="apple–converted–space"> </span><em>t</em><span class="apple–converted–space"> </span>test). Ease of gastric tube placement were much easier in IGEL than PLMA with (p=0.031). </span><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Incidence of complications were comparable.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:inter–ideograph;
line–height:200%"><b><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">CONCLUSION: </span></b><span style="font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif; background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial;">I–Gel is a supraglottic device with acceptable airway sealing pressure, easier to insert gastric tube and less sore throat incidence. Hence I–Gel can be a good alternative to PLMA.<o:p></o:p></span></p>

Keywords: Airway sealing pressure, I–gel, P LMA, time of insertion