Dr. Bhupesh Tirpude, Dr Avinash Rode, A study of Fine needle aspiration cytology in the evaluation of patients with radiographically occult palpable breast abnormalities, INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-6 | Issue-10 | October-2017
<p> </p>
<h1 style="text–align: justify; line–height: 200%; background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial;"><span style="font–size:12.0pt;line–height:200%;font–family:
"Arial","sans–serif";mso–fareast–font–family:"Times New Roman";font–weight:
normal;mso–bidi–font–weight:bold">The patients who present with radiographically occult palpable breast abnormalities represent a diagnostic challenge. Fine needle aspiration cytology (FNAC) could be an accurate method for diagnosing and excluding malignancy in these patients.<o:p></o:p></span></h1>
<h1 style="text–align: justify; line–height: 200%; background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial;"><span style="font–size:12.0pt;line–height:200%;font–family:
"Arial","sans–serif";mso–fareast–font–family:"Times New Roman";font–weight:
normal;mso–bidi–font–weight:bold"> </span></h1>
<h1 style="text–align: justify; line–height: 200%; background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial;"><span style="font–size:12.0pt;line–height:200%;font–family:
"Arial","sans–serif";mso–fareast–font–family:"Times New Roman"">Materials and Methods:<o:p></o:p></span></h1>
<h1 style="text–align: justify; line–height: 200%; background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial;"><span style="font–size:12.0pt;line–height:200%;font–family:
"Arial","sans–serif";mso–fareast–font–family:"Times New Roman";font–weight:
normal;mso–bidi–font–weight:bold">The records of all patients undergoing FNAC at our institution between Jan 1, 2016 and to 31<sup>st</sup> december 2016 were queried. 173 patients with 175 palpable breast masses without an imaging correlate were included.<o:p></o:p></span></h1>
<h1 style="text–align: justify; line–height: 200%; background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial;"><span style="font–size:12.0pt;line–height:200%;font–family:
"Arial","sans–serif";mso–fareast–font–family:"Times New Roman"">Results:<o:p></o:p></span></h1>
<h1 style="margin: 12pt 0in 6pt; text–align: justify; line–height: 200%; background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial;"><span style="font–size:12.0pt;line–height:200%;font–family:
"Arial","sans–serif";mso–fareast–font–family:"Times New Roman";font–weight:
normal;mso–bidi–font–weight:bold">Of 175 FNAC performed, 2 (1%) were malignant, 16 (9%) were suspicious, and 157 (90%) were benign (n = 75) or non–diagnostic (n = 82). All 16 suspicious FNAC had additional biopsy, of which 4 were malignant. FNAC led to the identification of 6 (3.4%) occult malignancies. At a median follow–up of 16.3 months, 1 patient within the benign cohort was found to have an incidental 2.5 mm cancer identified on reduction mammaplasty, which was unrelated to the index mass. The negative predictive value of FNAC in benign patients was 100%.<o:p></o:p></span></h1>
Keywords: FNAC, Breast