Original Research Paper Neonatology

Neonatal Mechanical Ventilation Our 1 Year Experience At A Rural Hospital

Prajakta Dekate Jayant Vagha Sachin Damke

Abstract

<p> <b style="text–align: justify;"><i><span lang="EN–IN" style="font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;">Background: </span></i></b><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;">Neonatal mortality accounts for nearly two thirds of infant mortality and half of under 5 mortalities in India. So, mechanical ventilation has become a must to enhance neonatal survival and is an essential component of neonatal intensive care. <b>Objective: </b></span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;">To determine the common indications and outcome of neonates requiring mechanical ventilation in neonatal intensive care unit. <b>Method:</b> This was a </span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;">Prospective</span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;"> Observational study conducted on neonates who required mechanical ventilation over a period of 1 year (</span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;">1st September 2015 –1st September 2016</span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;">). Neonates admitted in NICU, requiring mechanical ventilation after taking an informed consent were enrolled in our study. Clinical course of the neonate including Indication of Ventilation and Complications were observed and studied in NICU. Details were entered in predesigned validated proforma and</span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;"> </span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;">outcome as Survival/Death noted. <b>Results: </b>103 neonates were ventilated over a period of 1 year, of whom 47 (</span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;">45.6%)</span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;"> survived. </span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;">The most common indication of ventilation were Birth asphyxia (30.1%), neonatal sepsis (21.4%), respiratory distress syndrome (19.4%) and congestive heart failure (9.7%). Survival rate was maximum in neonates with birth weight >2.5kg (58.6%) and >1.5kg – 2.5kg (56.5%) and least in neonates with birth weight <1.5kg (14.3%). Most common complication were Ventilator associated pneumonia (48.7%) and Sepsis (40.54%). 45.6% of neonates survived. <b>Conclusion:<i> </i></b></span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;">Judicial use of neonatal intensive care measures in a developing country can result in a reduction of morbidity and mortality. </span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;text–justify:inter–ideograph;line–height:150%;mso–layout–grid–align:
none;text–autospace:none"><span lang="EN–IN" style="font–size: 12pt; line–height: 150%; font–family: "Times New Roman", serif;"><o:p></o:p></span></p>

Keywords: Mechanical ventilation, Respiratory distress syndrome