Original Research Paper Dental Science

Digital evaluation of accuracy of reattaching fractured dental stone teeth with cyanoacrylate adhesive.

Jitendra J. Mete Puttaraj T. Kattimani

Abstract

<p> <b><span lang="EN–GB">Aim:</span></b><span lang="EN–GB"> </span>Aim of the study was to digitally evaluate accuracy of reattaching fractured dental</p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none"><o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%">stone (type III gypsum product) teeth to dental casts using cyanoacrylate adhesive.<span lang="EN–GB"><o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none"><b><span lang="EN–GB">Methods and Material:</span></b><span lang="EN–GB"> </span>Ten mandibular dental stone casts were obtained using mandibular<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">dentulous rubber cast mold. Dental stone casts were modified to make four teeth (one incisor,<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">one canine, and two premolars) fracture prone by making them isolated and elongated. Modified<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">gypsum casts were scanned using 3D scanner (Ceramill Map400, Amann Girrbach AG). Three<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">out of four fracture prone teeth were fractured and reattached with cyanoacrylate. One unfractured premolar on each dental cast was used as control. After reattachment casts were<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">again scanned in same position using 3D scanner. Scanned data was used to digitally evaluate<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">dimensional changes in reattached gypsum teeth using 3D analysis software (PolyWorks,<o:p></o:p></p>
<p class="MsoNormal" style="margin–top:3.0pt;line–height:200%">InnvoMetric).<span lang="EN–GB"><o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none"><b><span lang="EN–GB">Results:</span></b><span lang="EN–GB"> </span>Mean displacement in X (mesiodistal), Y (occlussogingival), and Z (faciolingual) plane<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">for measured points (n=120 points) on reattached teeth were 0.0268 mm (SD 0.0082), 0.0482<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">mm (SD 0.0113), and 0.0047 mm (SD 0.0020) respectively. Mean displacement in 3D for<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">measured points on reattached teeth calculated as surface distance based on XYZ displacement<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">was 0.0615 mm (SD 0.0162). Two–way ANOVA test revealed no stastically significant difference of dimensional change after reattachment of teeth with different morphology.<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none"><b><span lang="EN–GB">Conclusions:</span></b><span lang="EN–GB"> </span>In the context of present study, it can be concluded that reattaching cleanly<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">fractured dental stone teeth (type III gypsum product) with cyanoacrylate adhesive results in<o:p></o:p></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none">clinically insignificant dimensional change.<o:p></o:p></p>
<p class="MsoNormal" style="margin–top:3.0pt;line–height:200%"><span lang="EN–GB"> </span></p>

Keywords: dental stone, cyanoacrylate, 3D superimposition