Original Research Paper Radiodiagnosis

STRAIN ELASTOGRAPHIC EVALUATION OF CARCINOMA BREAST WITH PATHOLOGICAL CORRELATION

Dr. Suresh Phatak Dr. Gaurav Mishra Dr. Nipun Gupta Dr. Parul Singhai Dr. Akhita Singhania Ms. Pallavi Phatak

Abstract

<p> <b><span lang="EN–IN" style="font–size:12.0pt;font–family:"Times New Roman","serif"">Aim &Objective</span></b><span lang="EN–IN" style="font–size: 12pt; font–family: "Times New Roman", serif;">: To evaluate the diagnostic accuracy of ultrasound strain elastography for diagnosis of malignant breast lesions.</span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
normal;mso–layout–grid–align:none;text–autospace:none"><b><span lang="EN–IN" style="font–size:12.0pt;font–family:"Times New Roman","serif"">Material and methods:</span></b><span lang="EN–IN" style="font–size:12.0pt;font–family:"Times New Roman","serif""> A cross sectional prospective study was carried out in the Department of Radiology, AVBRH Sawangi (meghe) wardha from April 2016 till November 2017. Eighty patients were selected according to predefined inclusion and exclusion criteria.Arietta 70S ultrasound machine was used for evaluation of patients.Pathological correlation was done by FNAC/ Biopsy/Histopathology.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
normal;mso–layout–grid–align:none;text–autospace:none"><b><span lang="EN–IN" style="font–size:12.0pt;font–family:"Times New Roman","serif"">Results:</span></b><span lang="EN–IN" style="font–size:12.0pt;font–family:"Times New Roman","serif";
mso–bidi–font–weight:bold"> 98.75% </span><span lang="EN–IN" style="font–size:
12.0pt;font–family:"Times New Roman","serif"">patients (n=79) were females; 1.25% patient (n=1) was male. Sensitivity, specificity and diagnostic accuracy of ultrasound strain elastography was calculated to 93.6%, 50%, and 92.5% respectively.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
normal;mso–layout–grid–align:none;text–autospace:none"><b><span lang="EN–IN" style="font–size:12.0pt;font–family:"Times New Roman","serif"">Conclusion:</span></b><span lang="EN–IN" style="font–size:12.0pt;font–family:"Times New Roman","serif";
mso–bidi–font–weight:bold"> </span><span lang="EN–IN" style="font–size:12.0pt;
font–family:"Times New Roman","serif"">ultrasound strain elastography is an accurate, reliable and non invasive technique in the assessment of malignant breast lesions.<o:p></o:p></span></p>

Keywords: breast lumps, ultrasound, strain elastography, malignant breast lesions