Dr Vikas Kamat, Dr Chhaya Shinde, A study of baseline exophthalmometry in the normal Indian population and its relationship to age, gender and height, INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-1 | January-2018
<p> </p>
<p class="MsoNormal" style="line–height:200%"><b style="mso–bidi–font–weight:
normal"><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:
"Calibri","sans–serif";mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:
minor–latin;mso–ansi–language:EN–IN">Purpose:</span></b><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:"Calibri","sans–serif";
mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:minor–latin;mso–ansi–language:
EN–IN"><span style="mso–spacerun:yes"> </span></span><span lang="EN–GB" style="color:black;mso–themecolor:text1">To study the relationship between exophthalmometric values with age, gender and height of the normal Indian population.</span><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:"Calibri","sans–serif";
mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:minor–latin;mso–ansi–language:
EN–IN"><o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><b style="mso–bidi–font–weight:
normal"><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:
"Calibri","sans–serif";mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:
minor–latin;mso–ansi–language:EN–IN">Methods:</span></b><span style="color:
black;mso–themecolor:text1;mso–ansi–language:EN–US">Cross–sectional, observational study </span><span lang="EN–GB" style="mso–bidi–font–size:12.0pt;
line–height:200%;mso–fareast–font–family:Calibri;color:black;mso–themecolor:
text1">of 2000 </span><span style="color:black;mso–themecolor:text1;mso–ansi–language:
EN–US">eyes of 1000</span><b style="mso–bidi–font–weight:normal"><span style="mso–bidi–font–size:12.0pt;line–height:200%;mso–fareast–font–family:Calibri;
color:black;mso–themecolor:text1"> </span></b><span style="color:black;
mso–themecolor:text1;mso–ansi–language:EN–US">subjects aged 5 years to 90 years, from January 2016 to December 2016 (12 months),at Tertiary Care Hospital.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span lang="EN–IN" style="mso–bidi–font–size:
12.0pt;line–height:200%;mso–fareast–font–family:Calibri;mso–bidi–font–family:
"Times New Roman";color:black;mso–themecolor:text1;mso–ansi–language:EN–IN">Subjects who already had undergone routine ophthalmic examination and no abnormality was detected during the examination were included.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="color:black;
mso–themecolor:text1;mso–ansi–language:EN–US">The data about age, gender and height was noted. Exophthalmometry was performed using the same Hertel exophthalmometer by the same researcher.</span><b style="mso–bidi–font–weight:
normal"><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:
"Calibri","sans–serif";mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:
minor–latin;mso–ansi–language:EN–IN"><o:p></o:p></span></b></p>
<p class="MsoNormal" style="line–height:200%"><b style="mso–bidi–font–weight:
normal"><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:
"Calibri","sans–serif";mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:
minor–latin;mso–ansi–language:EN–IN">Results:</span></b><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:"Calibri","sans–serif";
mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:minor–latin;mso–ansi–language:
EN–IN"> </span><em><span lang="EN–GB" style="mso–bidi–font–family:"Times New Roman";
mso–bidi–theme–font:minor–bidi;color:black;mso–themecolor:text1;background:
white">The baseline exophthalmometric values in the normal Indian study subjects were in the range of 8–21 mm.</span></em><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:"Calibri","sans–serif";
mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:minor–latin;mso–ansi–language:
EN–IN"><o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><b style="mso–bidi–font–weight:
normal"><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:
"Calibri","sans–serif";mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:
minor–latin;mso–ansi–language:EN–IN">Conclusions</span></b><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:"Calibri","sans–serif";
mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:minor–latin;mso–ansi–language:
EN–IN">: </span><em><span lang="EN–GB" style="mso–bidi–font–family:"Times New Roman";
mso–bidi–theme–font:minor–bidi;color:black;mso–themecolor:text1;background:
white">Age and gender may have influence on exophthalmometric values; however, height does not have any significance .</span></em><span lang="EN–IN" style="font–size:11.0pt;line–height:200%;font–family:"Calibri","sans–serif";
mso–ascii–theme–font:minor–latin;mso–hansi–theme–font:minor–latin;mso–ansi–language:
EN–IN"><o:p></o:p></span></p>
Keywords: Exophthalmometry, age, gender, height