Original Research Paper Dental Science

A Study on Evaluation Of Reliability Of angular Method Of Radiographic Localisation Of Impacted Maxilary Canine On Orthopantogram.

Dr Syeed Wakeel Dr(Prof.) Parveen Akhter Lone Dr Mohammed Israr Ul Khaliq Dr Shakiel ur Rehman

Abstract

<p> </p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><b><span lang="EN–GB" style="font–size:12.0pt;font–family:"Times New Roman","serif"">Objective:</span></b><span lang="EN–GB" style="font–size:12.0pt;font–family:"Times New Roman","serif"">To evaluate the reliability of angular method of localising the position of a impacted maxillary canine on orthopantogram(OPG).<b><o:p></o:p></b></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><span lang="EN–GB" style="font–size:12.0pt;font–family:"Times New Roman","serif""><o:p> </o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><b style="mso–bidi–font–weight:normal"><span lang="EN–GB" style="font–size:12.0pt;
font–family:"Times New Roman","serif"">Material and Methods: </span></b><span lang="EN–GB" style="font–size:12.0pt;font–family:"Times New Roman","serif"">20 subjects,7 males and 13 females with a total of 24 impactedcanines were evaluated. The angulation of the canine to the occlusion plane was measured using a panoramic radiograph .The angulation of the canine to the occlusal plane was measured using a panoramic radiograph; if the angulation was greater than 65°, it was presumed that impacted tooth is buccally positioned than a palatally impacted maxillary canine.. This radiographically predicted position is verified by intraoperative position of <span style="mso–spacerun:yes"> </span>tooth which is gold standard for comparison.<b style="mso–bidi–font–weight:normal"><o:p></o:p></b></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><span lang="EN–GB" style="font–size:12.0pt;font–family:"Times New Roman","serif""><o:p> </o:p></span></p>
<p class="MsoNormal" style="text–align:justify"><b><span lang="EN–GB" style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Result: </span></b><span lang="EN–GB" style="font–size:12.0pt;line–height:115%;
font–family:"Times New Roman","serif";mso–bidi–font–weight:bold">70 % of palatal placed canines were located accurately by angular method of localisation as compared to buccal placed impacted teeth which were accurately<span style="mso–spacerun:yes"> </span>localised in 30% only.<b><o:p></o:p></b></span></p>
<p class="MsoNormal" style="text–align:justify"><b><span lang="EN–GB" style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Conclusion :</span></b><span lang="EN–GB" style="font–size:12.0pt;line–height:115%;
font–family:"Times New Roman","serif";mso–bidi–font–weight:bold"> Angulation method is not reliable in accuratelydetermining the position of impacted teeth.However its usefulness<span style="mso–spacerun:yes"> </span>in determining the position of palataly placed teeth is more than that of<span style="mso–spacerun:yes"> </span>buccally impacted teeth.<o:p></o:p></span></p>

Keywords: Localization, Impacted Canine, Panoramic Radiograph, Magnification, Angulation