Dr Syeed Wakeel, Dr(Prof.) Parveen Akhter Lone, Dr Mohammed Israr Ul Khaliq, Dr Shakiel ur Rehman, A Study on Evaluation Of Reliability Of angular Method Of Radiographic Localisation Of Impacted Maxilary Canine On Orthopantogram., INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-1 | January-2018
<p> </p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><b><span lang="EN–GB" style="font–size:12.0pt;font–family:"Times New Roman","serif"">Objective:</span></b><span lang="EN–GB" style="font–size:12.0pt;font–family:"Times New Roman","serif"">To evaluate the reliability of angular method of localising the position of a impacted maxillary canine on orthopantogram(OPG).<b><o:p></o:p></b></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><span lang="EN–GB" style="font–size:12.0pt;font–family:"Times New Roman","serif""><o:p> </o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><b style="mso–bidi–font–weight:normal"><span lang="EN–GB" style="font–size:12.0pt;
font–family:"Times New Roman","serif"">Material and Methods: </span></b><span lang="EN–GB" style="font–size:12.0pt;font–family:"Times New Roman","serif"">20 subjects,7 males and 13 females with a total of 24 impactedcanines were evaluated. The angulation of the canine to the occlusion plane was measured using a panoramic radiograph .The angulation of the canine to the occlusal plane was measured using a panoramic radiograph; if the angulation was greater than 65°, it was presumed that impacted tooth is buccally positioned than a palatally impacted maxillary canine.. This radiographically predicted position is verified by intraoperative position of <span style="mso–spacerun:yes"> </span>tooth which is gold standard for comparison.<b style="mso–bidi–font–weight:normal"><o:p></o:p></b></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><span lang="EN–GB" style="font–size:12.0pt;font–family:"Times New Roman","serif""><o:p> </o:p></span></p>
<p class="MsoNormal" style="text–align:justify"><b><span lang="EN–GB" style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Result: </span></b><span lang="EN–GB" style="font–size:12.0pt;line–height:115%;
font–family:"Times New Roman","serif";mso–bidi–font–weight:bold">70 % of palatal placed canines were located accurately by angular method of localisation as compared to buccal placed impacted teeth which were accurately<span style="mso–spacerun:yes"> </span>localised in 30% only.<b><o:p></o:p></b></span></p>
<p class="MsoNormal" style="text–align:justify"><b><span lang="EN–GB" style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Conclusion :</span></b><span lang="EN–GB" style="font–size:12.0pt;line–height:115%;
font–family:"Times New Roman","serif";mso–bidi–font–weight:bold"> Angulation method is not reliable in accuratelydetermining the position of impacted teeth.However its usefulness<span style="mso–spacerun:yes"> </span>in determining the position of palataly placed teeth is more than that of<span style="mso–spacerun:yes"> </span>buccally impacted teeth.<o:p></o:p></span></p>
Keywords: Localization, Impacted Canine, Panoramic Radiograph, Magnification, Angulation