Dr. Abhishek A. Deole, Dr Nidhi Tiwari, Dr Y. Umesh, Comparative study of SRK/T, Holladay I, Olsen and Barrets Universal II IOL power calculation formulae for patients of senile cataract with axial myopia, INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-2 | February-2018
<p> </p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><u><span lang="EN–IN" style="font–size:12.0pt;
line–height:200%;font–family:"Arial","sans–serif"">Purpose:</span></u></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif""> To compare the accuracy of SRK/T, Holladay I, Olsen and Barrets Universal II IOL power calculation formulae in patients of senile cataract with axial myopia..<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><u><span lang="EN–IN" style="font–size:12.0pt;
line–height:200%;font–family:"Arial","sans–serif"">Methods:</span></u></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif""> A prospective clinical study was carried out on 50 eyes of 35 patients with an axial length from 24.5 to 31.87 mm including 21 (60%) males and 14(40%) females. Calculation of the IOL power to be implanted was done by SRK/T, Holladay I, Olsen and Barrets Universal II formulae. Mean error was calculated from the difference between the formula predicted refractive error and the actual post operative refractive error.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><u><span lang="EN–IN" style="font–size:12.0pt;
line–height:200%;font–family:"Arial","sans–serif"">Results:</span></u></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif""> There was no statistically significant difference between the mean errors of the four formulae used (p value 0.996).<span style="mso–spacerun:yes"> </span>In patients with axial length > 26 mm, SRK/T formula showed least mean error (0.26 ± 0.60) but with a statistically insignificant difference (p value 0.854).<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><u><span lang="EN–IN" style="font–size:12.0pt;
line–height:200%;font–family:"Arial","sans–serif"">Conclusion</span></u></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif"">: Cataract surgery in high myopes is challenging. The calculation of IOL power in patients with high axial myopia using the third or<span style="mso–spacerun:yes"> </span>the fourth generation formulas help in improvement of the accuracy of the calculation and decreasing the post operative refractive error. <o:p></o:p></span></p>
Keywords: myopia, cataract, mean error, IOL power calculation formulae