Original Research Paper Dental Science

A CBCT- BASED COMPARISION OF ROOT CANAL FILLING QUALITY FOLLOWING DIFFERENT INSTRUMENTATION & OBTURATION TECHNIQUES -AN IN-VITRO STUDY

Shashi Bhushan kumar Abhay Kumar Neeraj Kant Panwar Neeraj Solanki Himanshu Tomar Gajendra kumar vats

Abstract

<p class="MsoNormal" style="text–align:justify;line–height:115%;mso–layout–grid–align:
none;text–autospace:none"><b style="mso–bidi–font–weight:normal"><u><span lang="EN–IN" style="font–size:14.0pt;line–height:115%">AIM–</span></u></b><span lang="EN–IN" style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif";
mso–bidi–font–family:"Times New Roman";mso–bidi–theme–font:minor–bidi;
color:#231F20;mso–bidi–font–weight:bold">A CBCT based technique for quantitative evaluation of voidsin root canal fillings done after endodontic procedures</span><b style="mso–bidi–font–weight:normal"><u><span lang="EN–IN" style="font–size:14.0pt;
line–height:115%">OBJECTIVES</span></u></b><span lang="EN–IN" style="font–size:
14.0pt;line–height:115%">–</span><span lang="EN–IN" style="mso–bidi–font–weight:
bold">To find best quality of biomechanical preparation through hand vs. Rotary instrument.To find voids in two different obturation techniques i.e. single vs.<span style="mso–spacerun:yes"> </span>Thermoplasticized condensation.</span><b><span lang="EN–IN" style="font–size:13.0pt;mso–bidi–font–size:9.0pt;line–height:115%;
font–family:"Helvetica–Bold","sans–serif";mso–bidi–font–family:Helvetica–Bold;
color:black">Materials and Methods: </span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif";
mso–bidi–font–family:"Times New Roman";mso–bidi–theme–font:minor–bidi;
color:#231F20;mso–bidi–font–weight:bold">Forty maxillary premolars will be randomly divided into two groups, 20 teeth will be hand instrumented (H) and 20 will be instrumented with rotary instrument (ROT).Both the above groups will again be divided into 2 groups of 10 each on random basis</span><span lang="EN–IN" style="font–size:12.0pt;line–height:115%;color:#231F20;mso–bidi–font–weight:
bold">.</span><span lang="EN–IN" style="font–size:12.0pt;line–height:115%;
font–family:"Times New Roman","serif";mso–bidi–font–family:"Times New Roman";
mso–bidi–theme–font:minor–bidi;color:#231F20;mso–bidi–font–weight:bold">The “H–SC and ROT–SC” groups will be instrumented with hand ProTaper files and rotary system respectively and filled with SINGLE CONE compaction. The “H–TH and ROT–TH” groups will be instrumented with Hand ProTaper filesand rotary system respectively and filled with Thermoplasticized obturation system. The volume at the filling/dentine interface (i–voids) and voids surrounded by filling material (s–voids) will be measured using CBCT.The software used for calculating volume will be ANATOMAGE–INVIVO5 </span><span lang="EN–IN" style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif";
mso–bidi–font–family:"Times New Roman";mso–bidi–theme–font:minor–bidi;
mso–bidi–font–weight:bold">software (<em><span style="mso–bidi–font–family:
"Times New Roman";mso–bidi–theme–font:minor–bidi;background:white">Anatomage</span></em><span style="background:white">. 303 Almaden Blvd, Suite 700. San Jose, CA 95110).</span></span><b><span lang="EN–IN" style="font–size:13.0pt;mso–bidi–font–size:9.0pt;line–height:115%;
font–family:"Helvetica–Bold","sans–serif";mso–bidi–font–family:Helvetica–Bold;
color:black">Statistical Analysis:</span></b><span lang="EN–IN" style="font–size:
12.0pt;line–height:115%;font–family:"Times New Roman","serif";mso–bidi–font–family:
"Times New Roman";mso–bidi–theme–font:minor–bidi">The inter group comparison was done using the One Way ANOVA and Independent t–test.</span><b><span lang="EN–IN" style="font–size:13.0pt;mso–bidi–font–size:9.0pt;line–height:115%;
font–family:"Helvetica–Bold","sans–serif";mso–bidi–font–family:Helvetica–Bold;
color:black">Results:</span></b><span lang="EN–IN" style="font–size:12.0pt;
line–height:115%;font–family:"Times New Roman","serif";mso–bidi–font–family:
"Times New Roman";mso–bidi–theme–font:minor–bidi">hand instrumented canal obturated with Thermoplasticized technique was having less amount of volume of voids than Rotary instrumented and obturated with single cone technique. <b style="mso–bidi–font–weight:normal">Conclusion–</b></span><span lang="EN–IN" style="font–size:12.0pt;line–height:115%">Among the collected data Hand instrumented Canal was having less amount of volume of voids than Rotary instrumented.Single cone obturation technique was having highest amount of volume of voids than Thermoplasticized technique.<span style="color:#231F20;
mso–bidi–font–weight:bold"><o:p></o:p></span></span></p>

Keywords: Hand, Rotary, Single Cone, Thermoplasticized, CBCT, Voids