NASIR AHMAD LONE, FAYAZ AHMAD SOFI, NASEER A CHOH, TARIQ A GOJWARI, BILAL AHMAD RATHER, Role of High Resolution Ultrasonography and Colour Doppler in the evaluation of inflammatory arthropathy of peripheral joints with MRI correlation, INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-5 | May-2018
<p class="MsoNormal" style="line–height:200%"><b style="mso–bidi–font–weight:
normal">OBJECTIVE</b>: The study was undertaken to assess the diagnostic value of High Resolution Ultrasound with Colour Doppler in the evaluation of inflammatory <span style="mso–spacerun:yes"> </span>features of inflammatory arthropathywith MRI as reference method.</p>
<p class="MsoNormal" style="line–height:200%"><b style="mso–bidi–font–weight:
normal">METHODS</b>:<span style="mso–spacerun:yes"> </span>It was a prospective study conducted on 40 diagnosed patients <span style="mso–spacerun:yes"> </span>of inflammatory arthritis;30 RA , 7 gout, 1 SLE and 2 spondyloarthropathy patients. 40 joints were examined <span style="mso–spacerun:yes"> </span>for various inflammatory features of inflammatory arthropathy with USG and ColourDoppler and the findings were compared with those of contrast enhanced MRI.</p>
<p class="MsoNormal" style="line–height:200%"><b style="mso–bidi–font–weight:
normal">RESULTS: </b>With MRI as reference method, grey scale USG showed<span style="mso–spacerun:yes"> </span>sensitivity, specificity and accuracy of 94.1%, 16.6% and 82.5% respectively with poor agreement with MRI( kappa=0.13) for synovitis. On addition of Colour Doppler, the corresponding values were 79%, 83.3% and 77.5% respectively with moderate agreement with MRI. For detection of tenosynovitis, HRUS with Colour Doppler showed sensitivity, specificity and accuracy of 71.4%, 89.4% and 80.0% respectively with moderate level of agreement with MRI ( kappa=0.60).<span style="mso–spacerun:yes"> </span>A sensitivity, specificity and accuracy of 72.7%, 100.0% and 85.0% respectively were noted for detection of joint effusion with good agreement with MRI (kappa=0.70).</p>
<p class="MsoNormal" style="line–height:200%"><b style="mso–bidi–font–weight:
normal">CONCLUSION:</b> Although MRI is considered a reference imaging method for inflammatory arthritis, HRUS with Colour Doppler also shows good results for detection of inflammatory features of inflammatory arthropathy and could be a reasonably efficacious alternative to MRI.</p>
Keywords: Inflammatory arthritis, Rheumatoid arthritis, Ultrasonography, Colour Doppler, Magnatic resonance imagin