Dr Nagre Amarja S, Relationship Of Pump Flow And Expired Pump Co2 On Cardiopulmonary Bypass: An Observational Study, INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-5 | May-2018
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal">Aim–</b><span style="mso–spacerun:yes"> </span>To study the relationship of pump flow and expired pump Co<sub>2 </sub>(PepCo<sub>2</sub>)<span style="mso–spacerun:yes"> </span>on<span style="mso–spacerun:yes"> </span>cardiopulmonary bypass (CPB).</p>
<p class="MsoNormal"><o:p> </o:p></p>
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal">Background – </b>PepCo<sub>2</sub> (partial pressure of expired pump carbon dioxide) is a good correlator<span style="mso–spacerun:yes"> </span>of PaCo<sub>2</sub> during CPB. It is<span style="mso–spacerun:yes"> </span>established that PaCo<sub>2</sub> reflects cardiac output in a state of controlled ventilation.<b style="mso–bidi–font–weight:
normal"><o:p></o:p></b></p>
<p class="MsoNormal" style="text–indent:.5in">Hence, it was hypothesized that<span style="mso–spacerun:yes"> </span>PepCo<sub>2</sub> is an indicator of changes in pump flow (cardiac output) during CPB where oxygenator acts as an ideal lung.</p>
<p class="MsoNormal" style="text–indent:.5in"><o:p> </o:p></p>
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal">Methodology – </b>An observational study was conducted in 30 patients of either sex undergoing open heart<span style="mso–spacerun:yes"> </span>surgeries under CPB to establish the relation between PepCo<sub>2</sub> and pump flow.<span style="mso–spacerun:yes"> </span><b style="mso–bidi–font–weight:normal"><o:p></o:p></b></p>
<p class="MsoNormal" style="text–indent:.5in">Keeping<span style="mso–spacerun:yes"> </span>constant sweep flow rate and temperature<span style="mso–spacerun:yes"> </span>during CPB, PaCO<sub>2</sub> and PepCO<sub>2</sub> values were measured<span style="mso–spacerun:yes"> </span>at stable hypothermia<span style="mso–spacerun:yes"> </span>30<sup>o</sup>C . The variations in PepCo<sub>2</sub> were observed by adjusting the pump flow within the permissible range of cardiac index for that patient. The adequacy of perfusion was also assessed by measuring<span style="mso–spacerun:yes"> </span>SvO<sub>2</sub>, glucose, and lactate levels.</p>
<p class="MsoNormal" style="text–indent:.5in"><b style="mso–bidi–font–weight:
normal"><span style="mso–tab–count:1"> </span><o:p></o:p></b></p>
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal">Results</b> – It was observed that values of PepCO<sub>2</sub> correlated with the pump flow (p=0.011) and change in PepCO<sub>2</sub> has definite positive relationship with the change in<span style="mso–spacerun:yes"> </span>pump flow. One unit change in pump flow resulted in 0.97unit change in PepCO<sub>2</sub>.</p>
<p class="MsoNormal"><o:p> </o:p></p>
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal">Conclusion – </b>PepCo2 on cardiopulmonary bypass is a good continuous, non–invasive tool for monitoring adequacy of pump flow. Hence ,it is<span style="mso–spacerun:yes"> </span>recommended to<span style="mso–spacerun:yes"> </span>monitor PepCo<sub>2</sub> routinely during CPB.</p>
Keywords: cardiac output, PepCO2 (expired pump CO2 ), pump flow