Bharath Makonahally Jagannath, Sahadev Krishne Gowda, Sandeep Rudra Naik, Santhosh Sagar, Daniel Ninan, Remya Mohan, Effect of dentine desensitizing agents on the bond strength of composite resin to dentine. , INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-6 | June-2018
<p class="MsoListParagraph" style="margin–left:0in;mso–add–space:auto;text–align:
justify;text–justify:inter–ideograph;line–height:150%"><span style="font–size:
12.0pt;line–height:150%;font–family:"Times New Roman","serif"">Hypersensitivity is a common clinical multi–etiological problem. Many desensitizing treatments are there to overcome hypersensitivity. <span style="color:black;mso–themecolor:
text1">The aim of the study is </span>to evaluate the effect of desensitizing dentifrice containing sodium calcium phosphosilicate and Diode laser on the tensile bond strength of composite to dentine.<b><span style="color:black;
mso–themecolor:text1"><o:p></o:p></span></b></span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:inter–ideograph;
line–height:150%"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif"">Materials and Methods: </span></b><span style="font–size:12.0pt;line–height:150%;
font–family:"Times New Roman","serif"">Thirty sound human molars were used. Enamel was wet abraded to expose flat dentin surfaces and polished with sandpaper. The specimens were then divided into three groups (n = 10) based on the type of dentin–desensitizing treatment given. <b style="mso–bidi–font–weight:
normal"><o:p></o:p></b></span></p>
<p class="MsoNormal" style="margin–left:31.5pt;text–align:justify;text–justify:
inter–ideograph;text–indent:–13.5pt;line–height:150%"><span style="font–size:
12.0pt;line–height:150%;font–family:"Times New Roman","serif"">Group 1– was the control group where no desensitizing agent was used.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–left:31.5pt;text–align:justify;text–justify:
inter–ideograph;text–indent:–13.5pt;line–height:150%"><span style="font–size:
12.0pt;line–height:150%;font–family:"Times New Roman","serif"">Group 2–was treated with desensitizing dentifrice containing sodium calcium phosphosilicate. <o:p></o:p></span></p>
<p class="MsoNormal" style="margin–left:31.5pt;text–align:justify;text–justify:
inter–ideograph;text–indent:–13.5pt;line–height:150%"><span style="font–size:
12.0pt;line–height:150%;font–family:"Times New Roman","serif"">Group 3– was treated with Diode laser. <o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:inter–ideograph;
line–height:150%"><span style="font–size:12.0pt;line–height:150%;font–family:
"Times New Roman","serif"">Afterwards, the desensitized specimens were treated with one step self–etch adhesive (Tetric N Bond) according to manufacturer’s instructions and composite micro cylinders were packed. The specimens were then examined for tensile bond strength using universal tensile machine.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:inter–ideograph;
line–height:150%"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif"">Statistical analysis:</span></b><span style="font–size:12.0pt;line–height:150%;font–family:
"Times New Roman","serif"">The recorded values were subjected to statistical analysis using the SPSS software. One–way ANOVA, and Post–hoc Tukey HSD test were performed to evaluate the tensile bond strength values. For the entire evaluation, P < 0.05 was considered to be statistically significant.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:inter–ideograph;
line–height:150%"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif"">Results: </span></b><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif"">Higher tensile bond strength was seen in the control group when compared with the experimental groups<b style="mso–bidi–font–weight:normal"><o:p></o:p></b></span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:inter–ideograph;
line–height:150%"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif"">Conclusion: </span></b><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif"">Based on the results of this study, dentifrice and Laser pretreated dentin has lower tensile bond strength with resin composites as compared to dentin that is untreated<o:p></o:p></span></p>
Keywords: Sodium calcium phosphosilicate, Diode laser