Dr.Shyam Lal, Dr.Ramesh Chandra Sunar, Dr.Reema Meena, Comparative evaluation of Laryngeal mask airway supremetm and I-Geltm for peri and post operative complications, INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-6 | June-2018
<p> Objectives– this was a comparative evaluation of Laryngeal mask airway supremetm and I–Geltm for peri and post operative complications.</p>
<div>Study Design— this was a Hospital based, randomized, single blind Interventional study conducted in the department of Anaesthesiology, SMS</div>
<div>Medical college & attached group of hospitals, Jaipur,.Sample size was calculated to be 45 in each group(Laryngeal mask airway supremetm S</div>
<div>group and I–Geltm I group) at alpha error 0.05 & power 80% to verify the expected difference of 1.5(±2.5)sec. (as per seed article) in mean insertion</div>
<div>time among I GELTM group and LMA SupremeTM group.</div>
<div>Result and discussion: In our study we found that Airway trauma was observed only in one patient in group I and in two patients in group S. The</div>
<div>difference was statistically not significant (p=1.000). The perioperative complication which included Coughing, broncho & laryngospasm,</div>
<div>hypoxia, regurgitation/aspiration were noted. Coughing & bronchospasm was noted in one patient in group S. The difference was statistically not</div>
<div>significant (p=1.000). The post–operative complication (24 hr post surgery) which included blood staining/hoarseness of voice/sore</div>
<div>throat/difficulty in swallowing/vomiting were noted. Sore throat was noted in one patient in the group I & 3 in group S. Blood staining of the device</div>
<div>in one patient in the group I & 2 in group S. The difference was statistically not significant (p=1.000).</div>
<div>Conclusion: This study demonstrates that new Supraglottic airway devices I–GelTM and LMA SupremeTM were better alternative to</div>
<div>endotracheal tube in patients undergoing elective surgeries under general anesthesia. But peri and post operative complications were more in</div>
<div>Laryngeal mask airway supremetm group than I–Geltm group .Further multicentre mega trials were indicated to assess safety and performance</div>
<div>compared to other supraglottic airway devices.</div>