Original Research Paper Dental Science

Comparison Of The Effect Of Marginal Thickness On Linear Accuracy Of Impressions And Stone Dies Using Vinyl Polysiloxane Ether And Poly Vinyl Siloxane: An In Vitro Study

Dr.Pattanaik Bikash Dr. Nazirkar Girish S Dr. Padiyar Prasad R Dr. Farooqui AhmedFaraz M Dr. Sanap Vishakha P Dr. Bhosale Ashwini A

Abstract

<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Context: </span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman","serif"">Space available gingival retraction is 0.3–0.4mm. However, after 40s, only 0.2mm of it is available. This is a concern when multiple impressions have to be made.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%"><b><span lang="EN–IN" style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">Aim:</span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">To compare the effect of impression margin thickness made using poly vinyl siloxane(PVS) and vinyl siloxane ether(VSE) on the linear accuracy of impressions and stone dies. <b style="mso–bidi–font–weight:normal"><o:p></o:p></b></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Methodology: </span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman","serif";mso–fareast–font–family:"Times New Roman";
mso–bidi–font–weight:bold">A</span><span lang="EN–IN" style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif";mso–fareast–font–family:
"Times New Roman""> stainless–steel die was prepared with a square cavity in the centre with spaces of 4 varying widths. Ten impressions were made using VSE and PVS each and stone dies were poured.The accuracy of impressions and stone dies was measured.</span><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif""><o:p></o:p></span></b></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–fareast–font–family:"Times New Roman"">Results: </span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:black">Impressions with thin margin of 0.1 mm showed maximum distortion and the same was with the dies. One–way ANOVA for PVS showed significant difference (P<0.05) while with VSE showed highly significant difference (P<0.001).</span><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif";mso–fareast–font–family:
"Times New Roman""><o:p></o:p></span></b></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%"><b><span lang="EN–IN" style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif";mso–fareast–font–family:
"Times New Roman"">Conclusion: </span></b><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif";mso–ansi–language:EN–US">Theoverall accuracy of PVS was found to be high</span><span lang="EN–IN" style="font–size:
12.0pt;line–height:200%;font–family:"Times New Roman","serif""> and </span><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–ansi–language:EN–US">can be the preferred material of choice.</span><b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–fareast–font–family:"Times New Roman""><o:p></o:p></span></b></p>

Keywords: Margin thickness, linear accuracy, Poly vinyl Siloxane, Vinyl siloxanether, gingival retraction