Original Research Paper Anesthesiology

A Novel Technique of Epidural Catheter Fixation and Comparison between Three Different Approaches

Ruchi Singh Neha Vyas Chansoria Mayank Chansoria Peeyush Shivhare Chandan Sahu

Abstract

<p class="Standard" style="margin–bottom:10.0pt"><b style="mso–bidi–font–weight:
normal"><span lang="EN–IN" style="font–family:"Times New Roman","serif"">Introduction:</span></b><span lang="EN–IN" style="font–family:"Times New Roman","serif""> Numerous fixation devices have been designed to tether the catheter to the skin, including simple adhesive devices and more complex catheter clamps that adhere to the skin (Lockit ®, Portex, UK). Devices such as a balloon–tipped catheter (Patent No. US4973305) and a self– retaining catheter with wings that can be expanded outwards at the tip (Patent No. EP0931559) have not reached the market. It appears that the weak link in adhesive catheter fixation techniques is in the tethering of the adhesive to the skin.<o:p></o:p></span></p>
<p class="Standard" style="margin–bottom:10.0pt"><b style="mso–bidi–font–weight:
normal"><span lang="EN–IN" style="font–family:"Times New Roman","serif"">Aim and objectives</span></b><span lang="EN–IN" style="font–family:"Times New Roman","serif"">: Study was done to compare the traditional method of epidural catheter fixation, i.e, looping and tapping, used in our setup, with the newer techniques of fixation.<o:p></o:p></span></p>
<p class="Standard" style="margin–bottom:10.0pt;text–align:justify"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–family:"Times New Roman","serif"">Material and Methods</span></b><span lang="EN–IN" style="font–family:"Times New Roman","serif"">: 105 patients scheduled for elective abdominal (including<span style="mso–spacerun:yes"> </span>gynaecological) surgeries, in whom epidural catheter fixation by looping and tapping in group of 35 patients, by subcutaneous tunnelling in another group, and by subcutaneous tunnelling with suturing and loping in group C, was placed for surgery and for postoperative analgesia for a minimum period of 24 hrs.<o:p></o:p></span></p>
<p class="Standard" style="margin–bottom:10.0pt;text–align:justify"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–family:"Times New Roman","serif"">Results:</span></b><span lang="EN–IN" style="font–family:"Times New Roman","serif";color:black"> The tunneling and looping technique<span style="mso–spacerun:yes"> </span>showed<span style="mso–spacerun:yes"> </span>more decrease in the incidence of dislodgement as compared to the simple looping and taping fixation </span><span lang="EN–IN" style="font–family:"Times New Roman","serif";
mso–fareast–font–family:Arial;color:black">(p=0.04)</span><span lang="EN–IN" style="font–family:"Times New Roman","serif";color:black">. While the suturing and tunneling with looping technique showed no </span><span lang="EN–IN" style="font–family:"Times New Roman","serif";mso–fareast–font–family:Arial;
color:black">dislodgement.<o:p></o:p></span></p>

Keywords: Epidural catheter with 18 G Tuohy epidural needle and epidural catheter, synthetic nonfilament, non absorbable polyester suture, Thorasic and lumber epidural