Original Research Paper Dental Science

COMPARISON OF MICROLEAKAGE AND MICROSHEAR BOND STRENGTH OF A LOW SHRINKAGE COMPOSITE VERSUS METHACRYLATE BASED HYBRID COMPOSITE- AN IN VITRO STUDY

Dr. Anupreeta. A Dr. T.Rambabu Dr. Girija S Sajjan Dr. V R K R R Manikya Kumar Dr. Ravi Kumar Konagala Dr. Mohan RB

Abstract

<p> Purpose of the study: was to evaluate and compare, microleakage and micro–shear bond strength of low shrinkage novel composite [Silorane</p>
<div>FiltekTM P90] with that of conventional hybrid composite FILTEKTM Z250.</div>
<div>Methodology: For microleakage evaluation, standardized Class V cavities on extracted premolars were randomly assigned into 2 groups (n=10);</div>
<div>Gruop 1= FILTEKTM P90, Gruop 2= FILTEKTM Z250. Restored specimens were thermocycled and subjected to methylene blue dye penetration</div>
<div>following which, they were sectioned. microleakage was evaluated steromicroscopically and data was statistically analyzed using the Mann</div>
<div>whitney test. For micro–shear bond strength test, flat dentinal surface of 2 test groups(n=10) specimens were restored to create microcylinders and</div>
<div>were then subjected to micro–shear bond strength test at cross–head speed of 0.5 mm /min. The results were statistically analysed using Unpaired t</div>
<div>test.</div>
<div>Results: Group1 exhibited significantly decreased microleakage at cemental margin, as compared to Group 2. At enamel margin, there was no</div>
<div>statistical significance. In terms of overall microleakage, Silorane showed statistically significant lower values. The micro–shear bond strength of</div>
<div>Group1, was significantly higher, compared to Group 2.</div>
<div>Conclusion: Silorane composite FiltekTM P90 showed decreased microleakage and higher bond strength than FiltekTM Z250.</div>

Keywords: Microleakage, Micro–shear bond strength, Resin based composites (RBCs)