C. Narender Kumar, Utilization Study of Magnetic Resonance Image Scanner in a Tertiary Care Teaching Hospital, INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-6 | June-2018
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><span style="font–size:11.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:black;mso–themecolor:text1">Background</span></b><span style="font–size:
11.0pt;line–height:200%;font–family:"Times New Roman","serif";color:black;
mso–themecolor:text1">:<span style="mso–spacerun:yes"> </span>MRI facilityis a costly technology center in health care business. The right managerial decision<span style="mso–spacerun:yes"> </span>increases the productivity of MRI. The utilization studies of such costly equipment is essential. Estimating the use coefficient of an equipment is useful for health care manager as a management tool. <o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><span style="font–size:11.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:black;mso–themecolor:text1">Objectives:</span></b><span style="font–size:
11.0pt;line–height:200%;font–family:"Times New Roman","serif";color:black;
mso–themecolor:text1"> The <span style="mso–spacerun:yes"> </span>study was focused to estimate the workload of MRI scanner, to analyze the utilization hours and find out utilization coefficient(UC) of MRI.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><span style="font–size:11.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:black;mso–themecolor:text1">Methods: </span></b><span style="font–size:
11.0pt;line–height:200%;font–family:"Times New Roman","serif";color:black;
mso–themecolor:text1">It was an observational and cross–sectional study carried out in teaching tertiary care hospital. The number of scans performed in the duration six years collected. The average time taken for a scan was estimated. The MRI equipment was operated for 14 hours per day. The equipment operating hours were calculated over a period of one month.<span style="mso–spacerun:yes"> </span>The utilization co–efficient index was calculated.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><span style="font–size:11.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:black;mso–themecolor:text1">Results: </span></b><span style="font–size:
11.0pt;line–height:200%;font–family:"Times New Roman","serif";color:black;
mso–themecolor:text1">The total number of MRI scans were 38036 in six years. The time for each type of scan<span style="mso–spacerun:yes"> </span>was estimated. The total scanning time for 691 MRI scans was 15460minutes and 47 seconds, in one month. The turnaround time was 5528 minutes for 691 scans. The total time was 20988 min. 47 sec. The average time MRI operated was 11hours and 39 min. the UC of MRI was 48.54%.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b style="mso–bidi–font–weight:normal"><span style="font–size:11.0pt;line–height:
200%;font–family:"Times New Roman","serif";color:black;mso–themecolor:text1"><span style="mso–spacerun:yes"> </span>Conclusion:</span></b><span style="font–size:
11.0pt;line–height:200%;font–family:"Times New Roman","serif";color:black;
mso–themecolor:text1;mso–bidi–font–weight:bold">The audits revealed that in many hospitals equipments were underutilized.<span style="mso–spacerun:yes"> </span>Estimating UCI of all equipments is <span style="mso–spacerun:yes"> </span>helpful to enhance the utilization rate of high end equipment for policy decisions in the public hospital. <o:p></o:p></span></p>
Keywords: MRI, Use Coefficient Index