Original Research Paper Dental Science

COMPARATIVE IN VITRO EVALUATION OF FLEXURAL STRENGTH AND HARDNESS OF THREE FIXED PROSTHODONTICS PROVISIONAL CROWN MATERIALS

Dr. Shilpa.S.Dandekeri

Abstract

<p class="MsoNormal" style="text–align:justify;line–height:200%;mso–layout–grid–align:
none;text–autospace:none"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:black">Objectives:</span></b><span lang="EN–IN" style="font–size:14.0pt;
line–height:200%;font–family:"Times New Roman","serif";mso–bidi–language:KN;
mso–bidi–font–weight:bold"> To evaluate and compare the flexural strength and hardness of three<span style="mso–spacerun:yes"> </span>provisional crown after storing in artificial saliva and testing at intervals of 10 days. <o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%;mso–layout–grid–align:
none;text–autospace:none"><span lang="EN–IN" style="font–size:14.0pt;line–height:
200%;font–family:"Times New Roman","serif""><span style="mso–spacerun:yes"> </span><b style="mso–bidi–font–weight:normal"><span style="color:black">Study design:</span></b><span style="color:black"> A metal master mould<span style="mso–spacerun:yes"> </span>was fabricated to obtain samples of standard dimensions. The three provisional crown materials that will be tested in this study are Protemp™ IV (group PSC),Combo– LignTM (group CDC),and TempronTM (TSC). The specimens<span style="mso–spacerun:yes"> </span>were tested for<span style="mso–spacerun:yes"> </span>flexural tests were using universal testing and the micro hardness using microhardness tester. Statistically analysed by </span></span><span style="font–size:14.0pt;
line–height:200%;font–family:"Times New Roman","serif";color:black;mso–ansi–language:
EN–US">ANOVA test.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%;mso–layout–grid–align:
none;text–autospace:none"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:black">Results :</span></b><span lang="EN–IN" style="font–size:14.0pt;
line–height:200%;font–family:"Times New Roman","serif";color:black"> </span><span style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–ansi–language:EN–US">Flexural test<span style="mso–spacerun:yes"> </span>results showed that Group PSc (105.78 MPa) has the highest flexural strength followed by Group CDC (80.90 MPa), Group TSC (69.67 MPa). The hardness tests showed that Group CDC (95.40 KHN) has the highest hardness value followed by Group PSC (69.10 RHN), Group TSC (47.80 KHN) .<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%;mso–layout–grid–align:
none;text–autospace:none"><b style="mso–bidi–font–weight:normal"><span style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–ansi–language:EN–US"><span style="mso–spacerun:yes"> </span>Conclusion: </span></b><span style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–ansi–language:EN–US">Group <b style="mso–bidi–font–weight:normal">PSC</b> showed the highest flexural strength compared to others,and Group<b style="mso–bidi–font–weight:normal"><sup> </sup>PSC</b>.<o:p></o:p></span></p>

Keywords: flexural strength, microhardness, provisional crowns