AM ABBA, AI LADU, UAM Abjah, Comparison of Oxygen saturation in sickle anaemia patients in steady state with those in vaso-occlusive crisis., INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-7 | July-2018
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Background:</span></b><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif""> Sickle cell anaemia (SCA) is an inherited condition in which the abnormal haemoglobin molecule under sickling under low oxygen saturation. This leads to widespread micro–vascular occlusion and tissue hypoxia, which may manifest as recurrent episodes of painful bone crisis. <span style="color:#292526">Hypoxemia is a common finding in patients with SCA; </span>it <span style="color:#292526">is recognized as a marker for vaso–occlusive events, such as, acute chest syndrome, stroke and recurrent painful crisis.<o:p></o:p></span></span></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:#292526">Aims and Objectives: </span></b><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif";color:#292526">to compare the oxygen saturation of SCA patients in steady state with those in VOC, and to determine its relationship with some clinical parameters.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none"><b><span style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman","serif"">Materials and Methods: </span></b><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">This is a prospective cross–sectional study involving 102 adults with SCA in steady state and 61 with vaso–occlusive crisis carried out between January to July 2017. The <span style="color:#333333">oxygen saturation was recorded using a</span>finger pulse oximeter (Suaoki, Model FS20A).<span style="color:#292526"><o:p></o:p></span></span></p>
<p class="MsoNormal" style="line–height:200%"><b style="mso–bidi–font–weight:
normal"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Results: </span></b><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">There was significant difference between the pulse rate (p=0.005) and systolic blood pressure (p=0.02) of the VOC group compared with the steady state group. The mean SpO<sub>2</sub> level for subjects was 94.4% (±4.04), and was significantly lower when compared with the mean SpO<sub>2</sub> level for the Controls of 95.7% (±3.8)(p=0.04). There was significant correlation between SpO<sub>2 </sub>and age only amongst the subjects group; otherwise there was no correlation between SpO<sub>2 </sub>and other measured clinical parameters in both subjects and control group.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:#292526">Conclusion:<o:p></o:p></span></b></p>
<p class="MsoNormal" style="line–height:200%;mso–layout–grid–align:none;
text–autospace:none"><span style="font–size:12.0pt;line–height:200%;font–family:
"Times New Roman","serif";color:#292526"><span style="mso–spacerun:yes"> </span>A high prevalence of hypoxemia was observed during vaso–occlusive crisis compared to the steady state. Routine monitoring of </span><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:#333333">SpO<sub>2</sub></span><span style="font–size:12.0pt;line–height:
200%;font–family:"Times New Roman","serif";color:#292526"> is recommended, as it </span><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">will provide data on the consistency of patients <span style="color:#333333">SpO<sub>2</sub></span> measurements and allows for comparison during acute illness. <o:p></o:p></span></p>
Keywords: Hypoxemia, pulse oximetry, sickle cell anaemia, vaso–occlusive crises