Original Research Paper Medical Science

A Comparative Study of Termination of Pregnancy by Vaginal Misoprost and Intrauterine Rubber Catheter with Vaginal Misoprost.

Dr Meetali Parashar Dr Sanjeev Kumar Dr Rajesh Kumar Dr Malathi Char

Abstract

<p class="MsoNormal" style="margin–top:0in;margin–right:0in;margin–bottom:0in;
margin–left:.5in;margin–bottom:.0001pt;text–align:justify;line–height:150%;
mso–layout–grid–align:none;text–autospace:none"><b style="mso–bidi–font–weight:
normal"><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–bidi–language:HE">Background :</span></b><span style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif";mso–bidi–language:HE">Deliberate termination of pregnancy either by medical or by surgical method before the viability of the fetus is called Induction of abortion. World Health Organization, define abortion as pregnancy termination before 20 weeks’ gestation or with a fetus born weighing <500 gm. Rubber catheter has been widely used in India as an abortifacient, as mentioned in a case series of 200 midtrimester MTPs in the early eighties. <b style="mso–bidi–font–weight:normal"><o:p></o:p></b></span></p>
<p class="MsoNormal" style="margin–top:0in;margin–right:0in;margin–bottom:0in;
margin–left:.5in;margin–bottom:.0001pt;text–align:justify;line–height:150%;
mso–layout–grid–align:none;text–autospace:none"><b style="mso–bidi–font–weight:
normal"><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–bidi–language:HE">Methodology</span></b><span style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif";mso–bidi–language:HE">:</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
color:black"> This prospec</span><span style="font–size:14.0pt;line–height:
150%;font–family:"Times New Roman","serif";mso–bidi–language:HE">ti</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
color:black">ve compara</span><span style="font–size:14.0pt;line–height:150%;
font–family:"Times New Roman","serif";mso–bidi–language:HE">ti</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
color:black">ve study was conducted on 50 female pa</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–bidi–language:HE">ti</span><span style="font–size:14.0pt;line–height:150%;
font–family:"Times New Roman","serif";color:black">ents having pregnancy of 13–20 weeks desirous of MTP coming to the hospital were divided into 2 groups alterna</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–bidi–language:HE">ti</span><span style="font–size:14.0pt;line–height:150%;
font–family:"Times New Roman","serif";color:black">vely. Each group had 25 pa</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–bidi–language:HE">ti</span><span style="font–size:14.0pt;line–height:150%;
font–family:"Times New Roman","serif";color:black">ents each. Group A–Vaginal tablets Misoprost (400ug) was used every 4 hrly. Group B–Vaginal tablets Misoprost (400ug) was used along with intrauterine extraamnio</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–bidi–language:HE">ti</span><span style="font–size:14.0pt;line–height:150%;
font–family:"Times New Roman","serif";color:black">c rubber catheter placement.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–top:0in;margin–right:0in;margin–bottom:0in;
margin–left:.5in;margin–bottom:.0001pt;text–align:justify;line–height:150%;
mso–layout–grid–align:none;text–autospace:none"><b style="mso–bidi–font–weight:
normal"><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
color:black">Result :</span></b><span style="font–size:14.0pt;line–height:150%;
font–family:"Times New Roman","serif";color:black">In group A, 11 pa</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–bidi–language:HE">ti</span><span style="font–size:14.0pt;line–height:150%;
font–family:"Times New Roman","serif";color:black">ents ( 44%) had retained products of concep</span><span style="font–size:14.0pt;line–height:150%;
font–family:"Times New Roman","serif";mso–bidi–language:HE">ti</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
color:black">on. In group B, only 3 pa</span><span style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif";mso–bidi–language:HE">tie</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
color:black">nts (12%) had retained POC, rest expelled the products completely. The “p” value was 0.0255. 100% of group B pa</span><span style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif";mso–bidi–language:HE">ti</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
color:black">ents aborted within 12 hrs whereas only 3% pa</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–bidi–language:HE">ti</span><span style="font–size:14.0pt;line–height:150%;
font–family:"Times New Roman","serif";color:black">ents in Group A aborted within 12 hrs.”P” value was 0.0001.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–top:0in;margin–right:0in;margin–bottom:0in;
margin–left:.5in;margin–bottom:.0001pt;text–align:justify;line–height:150%;
mso–layout–grid–align:none;text–autospace:none"><b style="mso–bidi–font–weight:
normal"><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
color:black">Conclusion: </span></b><span style="font–size:14.0pt;line–height:
150%;font–family:"Times New Roman","serif";color:black">The combined use of vaginal Misoprost and extra amni</span><span style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif";mso–bidi–language:HE">ot</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
color:black">ic rubber catheter is more effec</span><span style="font–size:
14.0pt;line–height:150%;font–family:"Times New Roman","serif";mso–bidi–language:
HE">ti</span><span style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif";
color:black">ve, well tolerated, less expensive and superior to vaginal Misoprost alone in second trimester MTP up to 20weeks.<b style="mso–bidi–font–weight:
normal"><o:p></o:p></b></span></p>

Keywords: MTP, MESOPROST