Original Research Paper Dental Science

A comparative evaluation of marginal accuracy and colour stability of provisional restorations fabricated from one cold cure acrylic resin, two autopolymerizing resins and one Light cure resin provisional materials.

Dr Anuradha Mohite Dr Prasad Adhapure Dr Jitendra Shinde Dr Nimisha Barve Ashutosh Pai

Abstract

<p class="MsoNormal" style="text–align:justify;line–height:200%"><span lang="EN–IN" style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif"">The purpose of the present study was to </span><span style="font–size:14.0pt;
line–height:200%;font–family:"Times New Roman","serif";mso–ansi–language:EN–US;
mso–bidi–font–weight:bold">evaluate and compare the marginal accuracy and color stability of four commercially available provisional restorative materials including </span><span lang="EN–IN" style="font–size:14.0pt;line–height:200%;
font–family:"Times New Roman","serif"">one cold cure acrylic resin, two autopolymerizedbis– acrylic composite resins and one light–cured composite resin.Marginal discrepancy was measured by measuring the distance between the vertical reference line and crown margin of the restoration using a metallurgical microscope.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><span lang="EN–IN" style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif"">Marginal accuracy was found be in the following order.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><span style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–ansi–language:EN–US">Luxatemp>= Protemp IV > DPI >Revotek LC.</span><span lang="EN–IN" style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif""><o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%;tab–stops:411.0pt"><span lang="EN–IN" style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–fareast–font–family:Calibri">F</span><span lang="EN–IN" style="font–size:
14.0pt;line–height:200%;font–family:"Times New Roman","serif"">orty disc specimens of 10 X 2 mm diameter each from cold cure acrylic resin, Protemp IV, Luxatemp, Revotek LC were fabricated to evaluate color stability in tea solution and artificial saliva.</span><span style="font–size:14.0pt;line–height:200%;
font–family:"Times New Roman","serif";mso–ansi–language:EN–US">It was observed that there was least mean color change in the tea solution for cold cure acrylic resin.<o:p></o:p></span></p>

Keywords: marginal accuracy, color stability, provisional restorative materials