Dr.Anivesh Jain, Dr.Vipin Kumar Raghuwanshi, Dr Pushraj Patel, Dr.R. K. Jain, Dr.Lovely Jain, Dr. Kaveri Shaw Patel, The add on effect of Fentayl for post ceasarean analgesia : randomized double blind study, INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-9 | September-2018
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
200%;tab–stops:353.75pt"><span style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman","serif";color:#7030A0">Backfround and objective<i style="mso–bidi–font–style:normal">–<o:p></o:p></i></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
200%;tab–stops:353.75pt"><span style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman","serif"">Cesarean delivery patients require <span style="mso–spacerun:yes"> </span>more compelling reasons to achieve<span style="mso–spacerun:yes"> </span>optimal<span style="mso–spacerun:yes"> </span>postoperative<span style="mso–spacerun:yes"> </span>pain<span style="mso–spacerun:yes"> </span>relief becausethey need to ambulate, to be alert<span style="mso–spacerun:yes"> </span>and energetic enough to care for,<span style="mso–spacerun:yes"> </span>interact with and breastfeed their<span style="mso–spacerun:yes"> </span>new born. The aim of the study is to assess the motor and sensory results by single prick with addition of fentanyl with bupivaicane.<i style="mso–bidi–font–style:normal"><span style="color:#7030A0"><o:p></o:p></span></i></span></p>
<p class="MsoNormal" style="margin–top:.5pt;text–align:justify;line–height:200%"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:#7030A0">MATERIAL AND METHOD–<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–top:.5pt;text–align:justify;line–height:200%"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">With computer generated table randomly 80 parturientsselected between 20 and 30 yrs undergoing elective cesarean delivery who enrolled for the study.All those with any medical/surgical complications,comorbidities,with fetal complications or high risk pregnancy,not willing to participate were excluded.Two groups were formed 1.<b style="mso–bidi–font–weight:normal">Group B (Control group)</b>Received intrathecally 2ml of 0.5% hyperbaric bupivacaine with 0.25ml of Normal saline. <b style="mso–bidi–font–weight:normal"><o:p></o:p></b></span></p>
<p class="MsoNormal" style="margin–bottom:6.0pt;line–height:200%"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:
200%;font–family:"Times New Roman","serif"">2.Group BF (Study group) </span></b><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Received intrathecally 2ml of 0.5% hyperbaric bupivacaine with 0.25 ml of (12.5µg) fentanyl.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:6.0pt;line–height:200%"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">The study population evaluated under various parameters for effect of analgesia.<span style="color:black;letter–spacing:.1pt"><o:p></o:p></span></span></p>
<p class="MsoNormal" style="margin–bottom:6.0pt;line–height:200%"><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Result :The time taken in onset of analgesia(1.8±0.5 min VS 1.66±0.38 min, group B Vs group BF) and to achieve the highest level of analgesia (6.8±0.88 Vs 6.23±0.89,group B Vs group BF) is similar in both the group.But the two segment sensory regression was significantly high in study group(114.75±31.52 min) as compare to control group(86.63±17.11min)<span style="color:black;mso–themecolor:
text1">P<0.0001 HS.</span><span style="color:black;letter–spacing:.05pt"> The post anesthesia complications were Nausea/vomiting and shivering .(p>0.05)</span><b style="mso–bidi–font–weight:normal"><o:p></o:p></b></span></p>
<p class="MsoNormal" style="margin–bottom:6.0pt;text–align:justify;line–height:
200%"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">CONCLUSION:</span></b><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif""> Use of intrathcal fentanyl in a dose of 12.5µg will help in producing excellent quality and prolong <span style="mso–spacerun:yes"> </span>duration of analgesia with a single injection and with no major adverse effect on mother.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
200%;tab–stops:353.75pt"><span style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman","serif"">ABBREVIATION–<span style="color:black">HB–Hyperbaric bupivacaine,IB–Isobaric bupivacaine,IT–Intrathecal,IV–Intravenous,LA–Local anaesthetics,LSCS–Lower segment caesarean section,SAB–Subarachnoid block,</span>kg–kilogram,µg –microgram,ml– mililitre,min–minute,mg–miligram.<o:p></o:p></span></p>
Keywords: ASA, intrathcal fentanyl, hyperbaric bupivacaine, subarachnoid block