M.Ashok, R.Freethi, K.Vanitha, S.Syed ali fatima, Ischemia modified albumin an early serum biomarker in diagnosing acute coronary syndrome, INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7 | Issue-9 | September-2018
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">Background<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">Acute coronary syndrome comprises of about 20–23% of patients presenting at emergency department accounts for increasing mortality and morbidity world wide . Along with ECG and other clinical parameters, cardiac biomarkers do have an important role in the early diagnosis and management of patient with ACS. Ischemia modified albumin is one of the recently identified ischemic biomarker approved by U.S food and drug administration .<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">Aim and objective To measure IMA and CKMB levels in the patient with ACS.The<b style="mso–bidi–font–weight:
normal"><span style="background:white"> </span></b><span style="background:
white">role of IMA as an early marker in diagnosis of ACS when compare with CKMB.<o:p></o:p></span></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">Materials and methods<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">Study group includes 50 patients with ACS and 50 age and sex matched healthy controls. Serum IMA levels measured by cobalt binding assay method measured colorimetrically.serum albumin and creatinine kinase (CK–MB) measured by bromocresol green , <span style="mso–spacerun:yes"> </span>immune inhibition method respectively.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">Results <span style="mso–spacerun:yes"> </span>Serum IMA levels increased in early hours of ACS<span style="mso–spacerun:yes"> </span>(mean =115.05±17.55) when compared to healthy controls.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman","serif"">Conclusion <span style="mso–spacerun:yes"> </span>Increased<span style="mso–spacerun:yes"> </span>serum IMA levels in early hours of ACS can be used in the diagnosis of ACS along with ECG and other biomarker CKMB.<o:p></o:p></span></p>
Keywords: Acute coronary syndrome, Ischemia modified albumin, creatinine kinase –MB