Comparative Evaluation Of Tensile Bond Strength Of Three Different Elastomeric Impression Materials To Auto-Polymerizing Acrylic Resin Using Manufacturer Recommended And Two Universal Tray Adhesives‾An In-Vitro Study , Dr. Darshana Choubisa , INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-7|Issue-11| November-2018
<p> </p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%;mso–hyphenate:none"><b style="mso–bidi–font–weight:
normal"><span lang="EN–IN" style="font–size:10.0pt;line–height:200%;font–family:
"Times New Roman","serif";mso–fareast–language:AR–SA">Background and Objectives: </span></b><span lang="EN–IN" style="font–size:10.0pt;line–height:
200%;font–family:"Times New Roman","serif";mso–fareast–language:AR–SA">This study was conducted to evaluate and compare the tensile bond strength of three commercially available elastomeric impression materials to auto – <span style="letter–spacing:–.2pt">polymerizing methyl methacrylate resin material, using manufacturer recommended</span> adhesive and two different commercially available universal tray adhesives. </span><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:10.0pt;line–height:200%;font–family:"Times New Roman","serif"">Methods</span></b><span lang="EN–IN" style="font–size:10.0pt;line–height:200%;font–family:"Times New Roman","serif"">: Three different elastomeric impression materials, viz. two addition silicone <span style="letter–spacing:–.2pt">and one condensation</span> silicone of putty viscosity were used in the study. Three paint on tray adhesives, that is, one manufacturer recommended tray adhesive and two universal tray adhesives <span style="letter–spacing:–.1pt">were used. A total of 180 flat 10×10×10 mm<sup>3</sup> </span>specimens, were made from the auto–polymerizing methyl methacrylate custom tray material. They were divided into 3 groups of 30 each. Each group was further divided into following 3 subgroups of 10 each. A thin layer of tray adhesive was coated and dried. Elastomers were mixed according to manufacturer’s instructions and applied between the two acrylic plates maintaining a gap of 2mm. The tensile bond tests were conducted after 24 hours for each specimen at a crosshead speed of 5 mm/min until adhesion failure occurred. The bond strength was calculated as the maximum force at failure divided by the surface area of each plate. The data was first analyzed with ANOVA followed by <span style="color:black">Post hoc Tukey HSD comparison test.</span></span><span lang="EN–IN" style="font–size:10.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–fareast–language:AR–SA"> </span><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:10.0pt;line–height:200%;font–family:"Times New Roman","serif"">Results</span></b><span lang="EN–IN" style="font–size:10.0pt;line–height:200%;font–family:"Times New Roman","serif"">: In present study, for all impression materials tested, results obtained were as follows: TBS for Group 1 ranged from 0.242–1.619; Group 2 ranged from 0.221–1.272 and Group 3 ranged from 0.049–0.827 N/cm<sup>2</sup>. All results were statistically significant with p<0.05.</span><span lang="EN–IN" style="font–size:10.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–fareast–language:AR–SA"> </span><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:10.0pt;line–height:200%;font–family:"Times New Roman","serif"">Conclusions</span></b><span lang="EN–IN" style="font–size:10.0pt;line–height:200%;font–family:"Times New Roman","serif"">: This study showed that, the use of manufacturer recommended tray adhesive provides significantly higher bond strength values than those obtained with the universal tray adhesive tested. <o:p></o:p></span></p>
Keywords: Addition Silicone, Condensation Silicone, Tray Adhesive, Autopolymerizing methyl methacrylate resin, Tensile Bond Strength