Original Research Paper Clinical Research

COMPARISON OF SUBGLOTTIC SECRETION DRAINAGE ENDOTRACHEAL TUBE WITH CONVENTIONAL ENDOTRACHEAL TUBE IN PREVENTION OF VENTILATOR ASSOCIATED PNEUMONIA IN PATIENTS ADMITTED IN THE MEDICAL INTENSIVE CARE UNIT

DR.SHEENA MARY BOBAN DR.PRIYA B NAIK

Abstract

<p> </p>
<p class="MsoListParagraphCxSpFirst" style="margin–left:39.0pt;mso–add–space:
auto;text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><i style="mso–bidi–font–style:normal"><span lang="EN–IN" style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif"">Objective: </span></i></b><span lang="EN–IN" style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif"">To compare the effect of subglottic secretions drainage endotracheal tubes with conventional endotracheal tubes on the incidence of ventilator associated pneumonia in patients receiving mechanical ventilation.<o:p></o:p></span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin–left:39.0pt;mso–add–space:
auto;text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><i style="mso–bidi–font–style:normal"><span lang="EN–IN" style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif"">Design:</span></i></b><span lang="EN–IN" style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif""> A prospective, quasi experimental comparative study<o:p></o:p></span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin–left:39.0pt;mso–add–space:
auto;text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><i style="mso–bidi–font–style:normal"><span lang="EN–IN" style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif"">Setting:</span></i></b><span lang="EN–IN" style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif""> A 28 bed general ICU<o:p></o:p></span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin–left:39.0pt;mso–add–space:
auto;text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><i style="mso–bidi–font–style:normal"><span lang="EN–IN" style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif"">Patients:</span></i></b><span lang="EN–IN" style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif""> One hundred patients with an expected duration of mechanical ventilation > 48 hours were enrolled in the study.<o:p></o:p></span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin–left:39.0pt;mso–add–space:
auto;text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><i style="mso–bidi–font–style:normal"><span lang="EN–IN" style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif"">Intervention: </span></i></b><span lang="EN–IN" style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif"">Patients were randomly assigned to receive either a subglottic secretions drainage (ssd) endotracheal tube or a standard endotracheal tube.<o:p></o:p></span></p>
<p class="MsoListParagraphCxSpMiddle" style="margin–left:39.0pt;mso–add–space:
auto;text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><i style="mso–bidi–font–style:normal"><span lang="EN–IN" style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif"">Results:</span></i></b><span lang="EN–IN" style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif""> 48 patients were randomized to receive subglottic secretions drainage endotracheal tubes and 52 patients received standard endotracheal tubes (control group). The two groups were similar at the time of randomization with respect to demographic characteristics and severity of illness. Ventilator Associated Pneumonia was seen in 2 patients (4.20%) receiving subglottic secretions drainage and in 12 patients (23.10%) in the control group.<o:p></o:p></span></p>
<p class="MsoListParagraphCxSpLast" style="margin–left:39.0pt;mso–add–space:auto;
text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><i style="mso–bidi–font–style:normal"><span lang="EN–IN" style="font–size:14.0pt;
line–height:150%;font–family:"Times New Roman","serif"">Conclusion:</span></i></b><span lang="EN–IN" style="font–size:14.0pt;line–height:150%;font–family:"Times New Roman","serif""> Intermittent subglottic secretion drainage reduces the incidence of VAP in patients receiving mechanical ventilation.<o:p></o:p></span></p>

Keywords: mechanical ventilation, aspiration, subglottic secretion drainage, ventilator– associated pneumonia