A COMPARATIVE ANALYSIS OF THE CLINICAL AND FUNCTIONAL OUTCOME OF HIGH-FLEX AND CONVENTIONAL KNEE PROSTHESIS: AT ONE YEAR, A FOLLOW-UP STUDY, Dr. Kishore Raichandani, Dr. Prem Manohar Seervi, Dr. Hemant Jain, Dr. Mohd. Arif, Dr. Madhu Sudan Sharma, Dr. Ravi Kumar Rana INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-8 | Issue-1 | January-2019
<p> </p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><b><span style="font–size:14.0pt;font–family:"Times New Roman","serif";color:black;
mso–ansi–language:EN–US">Purpose– </span></b><span style="font–size:14.0pt;
font–family:"Times New Roman","serif";color:black;mso–ansi–language:EN–US">The aim of this study was to compare the clinical and functional outcome of high flexion knee prosthesis with a conventional prosthesis.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><b><span style="font–size:14.0pt;font–family:"Times New Roman","serif";color:black;
mso–ansi–language:EN–US">Method– </span></b><span style="font–size:14.0pt;
font–family:"Times New Roman","serif";color:black;mso–ansi–language:EN–US">30 patients who were operated with conventional knee prosthesis kept under group A and group B have 30 patients operated with high flex knee prosthesis. The knee society score and range of motion were assessed periodically. Radiographs were evaluated to identify radiolucent line at bone cement interface, patella tracking, tibiofemoral alignment and implant position<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><b><span style="font–size:14.0pt;font–family:"Times New Roman","serif";color:black;
mso–ansi–language:EN–US">Results– </span></b><span style="font–size:14.0pt;
font–family:"Times New Roman","serif";color:black;mso–ansi–language:EN–US">At one year follow up the conventional prosthesis group had mean ROM of 108</span><span style="font–size:14.0pt;font–family:Ebrima;mso–ascii–font–family:"Times New Roman";
mso–bidi–font–family:"Times New Roman";color:black;mso–ansi–language:EN–US">⁰</span><span style="font–size:14.0pt;font–family:"Times New Roman","serif";color:black;
mso–ansi–language:EN–US"> and high flex group had mean ROM 110</span><span style="font–size:14.0pt;font–family:Ebrima;mso–ascii–font–family:"Times New Roman";
mso–bidi–font–family:"Times New Roman";color:black;mso–ansi–language:EN–US">⁰</span><span style="font–size:14.0pt;font–family:"Times New Roman","serif";color:black;
mso–ansi–language:EN–US">. No knee had aseptic loosening, deep infection or osteolysis. No significant difference was found in mean knee society score of both groups.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:normal;mso–layout–grid–align:none;text–autospace:none"><b><span style="font–size:14.0pt;font–family:"Times New Roman","serif";color:black;
mso–ansi–language:EN–US">Conclusion– </span></b><span style="font–size:14.0pt;
font–family:"Times New Roman","serif";color:black;mso–ansi–language:EN–US">The high flexion prosthesis revealed no significant difference over the conventional prosthesis in terms of KSS and ROM.<o:p></o:p></span></p>
Keywords: Total knee arthroplasty, Range of motion(ROM), conventional (Standard knee prosthesis), high flex knee prosthesis, Knee society score(KSS)