AN EVALUATION OF NON-INFECTIOUS ADVERSE REACTIONS FOLLOWING BLOOD TRANSFUSION AT A TERTIARY CARE REFERRAL TEACHING HOSPITAL IN SOUTHERN INDIA., Sindhuja K, SreedharBabu KV, Anitha M, Praveen MD, Sriranjitha TVN INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-8 | Issue-2 | February-2019
<p> </p>
<p class="MsoNormal" style="text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:
150%;font–family:"Times New Roman","serif";mso–fareast–font–family:"Times New Roman"">Back ground:</span></b><span style="font–size:12.0pt;line–height:150%;font–family:
"Times New Roman","serif""> Though blood transfusion is life saving, it can also lead to certain adverse reactions which can be fatal rarely.</span><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–fareast–font–family:"Times New Roman""> Identification of the adverse reactions will help in taking appropriate steps to reduce their incidence and make blood transfusion process as safe as possible and this study has been undertaken to </span><span style="font–size:12.0pt;line–height:150%;font–family:
"Times New Roman","serif"">assess the frequency of adverse reactions occurring following whole blood or blood component transfusion in patients admitted at a tertiary care<span style="mso–spacerun:yes"> </span>referral teaching hospital in Southern India.</span><span style="font–size:12.0pt;line–height:150%;
font–family:"Times New Roman","serif";mso–fareast–font–family:"Times New Roman""><o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:150%;mso–layout–grid–align:none;text–autospace:none"><b><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–fareast–font–family:"Times New Roman"">Material and Methods:</span></b><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–fareast–font–family:"Times New Roman""> During the period of one year all the adverse reactions related to transfusion of blood and blood components in patients admitted at our hospital were recorded. They were analyzed and classified using standard definitions, based on their clinical features and laboratory tests.<o:p></o:p></span></p>
<p class="MsoNormal" style="mso–margin–top–alt:auto;mso–margin–bottom–alt:auto;
text–align:justify;line–height:150%;mso–outline–level:3"><b><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–fareast–font–family:"Times New Roman"">Results:</span></b><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–fareast–font–family:"Times New Roman""> During the study period, a total of 13,532 whole blood and blood components were issued from our blood bank to 4,155 patients. Among them 23 (0.16%) adverse reactions were noted. The most common type of reaction observed was allergic (<span style="mso–bidi–font–style:
italic">n</span> = 9; 39.13%), followed by delayed hemolytic transfusion reaction (DHTR) (<span style="mso–bidi–font–style:italic">n</span> = 4; 17.39%).Other reactions observed were febrile non hemolytic transfusion reactions (FNHTRs) (n=3, 13.04%), hypotension (n=3, 13.04%),transfusion associated circulatory overload (TACO) (<span style="mso–bidi–font–style:italic">n</span> = 1, 4.35%), transfusion related acute lung injury (TRALI) (<span style="mso–bidi–font–style:
italic">n</span> = 1, 4.35%) and delayed serological transfusion reaction (DSTR)(<span style="mso–bidi–font–style:italic">n</span> = 2, 8.70%).<o:p></o:p></span></p>
<p class="MsoNormal" style="mso–margin–top–alt:auto;mso–margin–bottom–alt:auto;
text–align:justify;line–height:150%;mso–outline–level:3"><b style="mso–bidi–font–weight:
normal"><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–fareast–font–family:"Times New Roman"">Conclusion:</span></b><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif""> Frequency of transfusion reactions in the present study was 0.16%.</span><span style="font–size:12.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–fareast–font–family:"Times New Roman"">This can be an underestimation of the true incidence because of underreporting which can be improved by hemovigilance system and one should consider for rationale use of whole blood and blood components.<o:p></o:p></span></p>
Keywords: Adverse transfusion reactions, blood transfusion, hemovigilance