INTRACAPUSULAR NECK OF FEMUR FRACTURE TREATED WITH DYNAMIC HIP SCREW AND ANTIROTATION SCREW: A RETROSPECTIVE ANALYSIS, DR. SUJAY KUMAR DAS, DR. ANIRUDHYA DAS, DR. SUVROJYOTI SIL INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH : Volume-8 | Issue-3 | March-2019
<p> </p>
<p class="MsoNoSpacing" style="text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><span style="font–family:"Times New Roman","serif"">Background:</span></b><span style="font–family:"Times New Roman","serif""> </span><span lang="EN–IN" style="font–size:13.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–ansi–language:EN–IN">Internal fixation is the primary treatment choice<sup> </sup>in younger age group suffering from </span><span style="font–size:13.0pt;
line–height:150%;font–family:"Times New Roman","serif"">fracture neck femur</span><span lang="EN–IN" style="font–size:13.0pt;line–height:150%;font–family:"Times New Roman","serif";
mso–ansi–language:EN–IN">. But rate of failure of internal fixation in neck of femur fractures is high despite all measures.</span><span style="font–size:
13.0pt;line–height:150%;font–family:"Times New Roman","serif""> Fixation can be done by using three cannulated hip screws or by dynamic hip screw with or without a derotation screw. The outcomes of fracture neck of femur in young patients treated with Dyanamic Hip Screw (DHS) with a de–rotation were analyzed.<o:p></o:p></span></p>
<p class="MsoNoSpacing" style="text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><span style="font–size:13.0pt;line–height:
150%;font–family:"Times New Roman","serif"">Materials and methods:</span></b><span style="font–size:13.0pt;line–height:150%;font–family:"Times New Roman","serif""> The study was conducted on 54 patients were selected based on pre–determined eligibility criteria. The dynamic hip screw was inserted with a standard technique by means of a straight lateral incision on the lateral aspect of the thigh and hip. <o:p></o:p></span></p>
<p class="MsoNoSpacing" style="text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><span style="font–size:13.0pt;line–height:
150%;font–family:"Times New Roman","serif"">Result:</span></b><span style="font–size:13.0pt;line–height:150%;font–family:"Times New Roman","serif""> shows effect of dynamic hip screw with derotation screw is good.<o:p></o:p></span></p>
<p class="MsoNoSpacing" style="text–align:justify;line–height:150%"><b style="mso–bidi–font–weight:normal"><span style="font–size:13.0pt;line–height:
150%;font–family:"Times New Roman","serif"">Conclusion </span></b><span style="font–size:13.0pt;line–height:150%;font–family:"Times New Roman","serif"">: Osteosynthesis of intra–capsular femoral neck fracture with dynamic hip screw with derotation screw is good. <o:p></o:p></span></p>
Keywords: Fracture neck femur, Dynamic Hip Screw, Antirotation Screw