Original Research Paper Dental Science

Measurement of the average weight of conventional complete dentures processed with acrylic resin base material and the associated clinical significance

Dr. Manu Rathee Dr.Prachi Jain Dr. Renu Kundu Dr. Vipul Agarkar Dr. Smriti Kaushik

Abstract

Objective: To determine the average weight of conventional complete dentures processed with acrylic resin base material and the associated clinical significance
Materials and methodology: Weight of a total of 200 complete dentures; 100 ideal dentures fabricated by pre clinical students and 100 mucosal borne complete dentures fabricated for patients; was measured in a caliberated glass jar. The weights of maxillary and mandibular complete dentures were compared and association between age, gender and duration of edentulousness was seen.
Results: The average weight of maxillary and mandibular patient’s dentures was found to be 13.46 ±3.90 gm and 11.33±3.07 gm respectively. The average weight of ideal maxillary and mandibular dentures was found to be 17.7 ±3.21gm and 15.11±3.44 gm respectively.
Conclusion: The average weight of maxillary denture was more than that of mandibular denture in ideal as well patients’ denture.

Keywords: Average weight, conventional complete denture, Acrylic resin base material