Original Research Paper Medical Sci

Comparative Results of Gender Knee with Standard High Flexion Joints

Dr. Hiren K Patel Dr. Ankit Kediya Dr. H.P. Bhalodiya

Abstract

Women constitute majority of the patients with osteoarthritis. There are certain anatomical differences
between both sex.Gender specific femoral implants are specifically contoured according to the female femoral
surface and provide a better fit for the narrower female femur. This is a prospective study of 105 consecutive total knee replacements
performed in 80 female patients using hi-flexion knee implants at our institute by a single operating surgeon. The patients were followed up for an average 1.3 years for gender hi-flexion knee with a maximum follow-up of 2.8 years. While for other hi-flexion knees
average follow-up was 2 years with a maximum follow-up of 3.1 years. There was no statistically significant difference was found in
terms of Knee Society Score , range of motion , anterior knee pain or complications. It is possible that gender-specific implants might
have better outcomes for women. But to assess whether these implants have a clinically meaningful difference, studies are needed
which compare these specialized prostheses with gender-neutral implants at longer follow-up duration.

Keywords: gender specific, anterior knee pain, knee society score, hi flexion