Original Research Paper Medical Science

Comparative Study Between Clinical And Ultrasonographic Estimation Of Fetal Weight And Its Correlation With Actual Birth Weight.

DR.SOWMYA B S DR. REENA DR. SARITA DR. RAJAGOPAL

Abstract

Objective:To make comparative evaluation of estimation of fetal weight in term pregnancy by using a) abdominal
girth * symphysiofundal height
b) Hadlock’s formula using ultrasound c) Johnson’s formula d) dawn’s formula
Methods: fetal weight in utero is calculated by using above methods in 200 term pregnant women and the results were correlated with actual
birth weight. Comparison done by various methods.
Results: average error was least in AG*SFH method. Maximum error was in Dawns formula and least in AG*SFH and Hadlocks i.e.75.9% of
cases came within 30% of birth weigth by both AG*SFH and Hadlocks method. Standard deviation of predicyion error was least with Hadlocks methof followed by AG*SFH.
Conclusion: AG*SFH is the best predictor and is used in day to day practice. Hadlocks method had more accuracy but is done in places where
facilities are available.