Saket Nigam, Namrata Nigam, Ashok Kumar Singh CTGuided Percutaneous Biopsy of Intrathoracic Lesions : 5 years experience International Journal of Scientific Research,Volume : 5 | Issue : 10 | October 2016
<p> Aim: Evaluate diagnostic yield and complications of percutaneous transthoracic biopsy using a coaxial system. Materials and methods: Records of 200 patients who underwent percutaneous CT–guided coaxial cutting needle lung or mediastinal biopsy were retrospectively evaluated. Results: From lesions biopsied in 200 patients, histopathology reports were achieved in192 patients (96%) of which 159 biopsy results (79.5%) demonstrated malignancy. Complications were observed in 45 patients (22.5%). Only those patients which required post procedure admission or any active intervention were considered in complication list. Conclusion: Percutaneous lung and mediastinal biopsy using a coaxial system is a minimally invasive procedure with high diagnosis rate and an acceptable rate of complications.</p>
Keywords: coaxial biopsy needle, pneumothorax, hemoptysis