Original Research Paper Dental Science

COMPARATIVE EVALUATION OF THE VICKERS MICRO HARDNESS AND DEPTH OF CURE OF SELECTED DENTAL COMPOSITES - An In vitro study

Dr Anupama S Gopinathan Dr Jeeva P P Dr. Vinayakumar T

Abstract

<p> <b style="text-align: justify;"><span style="font-size:12.0pt;line-height:
200%;font-family:"Times New Roman","serif"">Aims and objectives</span></b></p>
<p class="MsoNoSpacing" style="text-align:justify;line-height:200%"><span style="font-size:12.0pt;line-height:200%;font-family:"Times New Roman","serif""> The current invitro study evaluated Vickers microhardness (VH) and depth of cure (DC) of selected dental composite resins polymerized with either a commercial halogen LCU or LED, LCU respectively.<o:p></o:p></span></p>
<p class="MsoNoSpacing" style="text-align:justify;line-height:200%"><b><span style="font-size:12.0pt;line-height:
200%;font-family:"Times New Roman","serif"">Materials and Methods<o:p></o:p></span></b></p>
<p class="MsoNoSpacing" style="text-align:justify;text-indent:.5in;line-height:
200%"><span style="font-size:12.0pt;line-height:200%;font-family:"Times New Roman","serif"">Five dental composite resins were selected for measuring VH (Spectrum TPH, Filtek <sup>TM </sup>P60, Z<sub>100</sub>, Chitra dual cure, Chitra radioopaque light cure). Four resin composites were investigated for depth of cure measurement. The VH of the surface was determined with a microhardness tester (HMV 2000 SHIMADZU) using a Vickers diamond indenter and a 1kg load applied for 20 sec. Depth of cure was measured using the digimatic calipers.<o:p></o:p></span></p>
<p class="MsoNoSpacing" style="text-align:justify;line-height:200%"><b><span style="font-size:12.0pt;line-height:
200%;font-family:"Times New Roman","serif"">Results<o:p></o:p></span></b></p>
<p class="MsoNoSpacing" style="text-align:justify;line-height:200%"><span style="font-size:12.0pt;line-height:200%;font-family:"Times New Roman","serif""> The results were compared statistically using one way ANOVA for VH. All samples showed statistically significant higher VH values for LED LCU except Z<sub>100</sub> which exhibited no difference. The mean values were taken into consideration for depth of cure. All samples except Z<sub>100</sub>showed higher mean value for LEDLCU.<o:p></o:p></span></p>
<p class="MsoNoSpacing" style="text-align:justify;line-height:200%"><b><u><span style="font-size:12.0pt;
line-height:200%;font-family:"Times New Roman","serif"">Conclusion<o:p></o:p></span></u></b></p>
<p class="MsoNoSpacing" style="text-align:justify;line-height:200%"><span style="font-size:12.0pt;line-height:200%;font-family:"Times New Roman","serif""> In summary VH and DC of samples cured with Halogen LCU and LED LCU exceeded the values required by ISO standards, manufacturers specifications and clinical demands.<o:p></o:p></span></p>

Keywords: Blue light emitting diodes, Vickers Hardness, Depth of cure