Original Research Paper Pharmacy

AN RP- HPLC METHOD DEVELOPMENT AND VALIDATION OF TRIAMTERENE AND BENZTHIAZIDE IN BULK AND PHARMACEUTICAL DOSAGE FORMS

M.Purushothaman M.Rajasekaran Rajesh Asija

Abstract

<p class="MsoNormal" style="text-align:justify;text-justify:inter-ideograph;
line-height:150%"><span style="font-size:12.0pt;line-height:150%;font-family:
"Times New Roman","serif"">A rapid and precise reverse phase high performance liquid chromatographic method has been developed for the validated of </span><span style="font-size:12.0pt;line-height:150%;font-family:"Times New Roman","serif";
mso-bidi-font-family:"Times New Roman";mso-bidi-theme-font:minor-bidi">Triamterene and Benzthiazide</span><span style="font-size:12.0pt;line-height:150%;
font-family:"Times New Roman","serif"">, in its pure form as well as in tablet dosage form. Chromatography was carried out on a Symmetry C18 (4.6 x 150mm, 5µm) column using a mixture of Methanol: Phosphate Buffer pH 3.5 (75:25) as the mobile phase at a flow rate of 1.0ml/min, the detection was carried out at 271 nm. The retention time of the </span><span style="font-size:12.0pt;line-height:
150%;font-family:"Times New Roman","serif";mso-bidi-font-family:"Times New Roman";
mso-bidi-theme-font:minor-bidi">Triamterene and Benzthiazide</span><span style="font-size:12.0pt;line-height:150%;font-family:"Times New Roman","serif"">was </span><span style="font-size:12.0pt;line-height:150%;font-family:"Times New Roman","serif";
mso-fareast-font-family:Calibri">2.344, 3.282 </span><span style="font-size:
12.0pt;line-height:150%;font-family:"Times New Roman","serif"">±0.02min respectively. The method produce linear responses in the concentration range of 10-50mg/ml of </span><span style="font-size:12.0pt;line-height:150%;font-family:
"Times New Roman","serif";mso-bidi-font-family:"Times New Roman";mso-bidi-theme-font:
minor-bidi">Benzthiazide</span><span style="font-size:12.0pt;mso-bidi-font-size:
14.0pt;line-height:150%;font-family:"Times New Roman","serif""> and 20-100mg/ml of </span><span style="font-size:12.0pt;line-height:150%;font-family:"Times New Roman","serif";
mso-bidi-font-family:"Times New Roman";mso-bidi-theme-font:minor-bidi">Triamterene</span><span style="font-size:12.0pt;line-height:150%;font-family:"Times New Roman","serif"">. The method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of bulk and pharmaceutical formulations.<o:p></o:p></span></p>

Keywords: Triamterene, Benzthiazide, RP-HPLC, validation