				<article-title>SIMULTANEOUS DETERMINATION OF METFORMIN AND REPAGLINIDE IN BULK AND TABLETS BY RP-HPLC METHOD</article-title>
			</title-group>
			<contrib-group><contrib contrib-type="author">
						<name>
							<surname>Sai</surname>
							<given-names>Jahnavi</given-names>
							<prefix>Dr.</prefix>
						</name>
						<xref ref-type="aff" rid="aff000">
							<sup></sup>
						</xref>
						</contrib><contrib contrib-type="author">
						<name>
							<surname>Yeluri</surname>
							<given-names>Ramachandra Reddy</given-names>
							<prefix>Dr.</prefix>
						</name>
						<xref ref-type="aff" rid="aff002">
							<sup></sup>
						</xref>
						</contrib></contrib-group><pub-date pub-type="ppub">
				<month>October</month>
				<year>2016</year>
			</pub-date>
			<volume>5</volume>
			<issue>10</issue>
			<fpage>01</fpage>
			<lpage>02</lpage>
			<abstract>
				<title>ABSTRACT</title>
				<p>&amp;lt;p&amp;gt;&amp;amp;nbsp;The present communication describes a rapid, precise and accurate RP-HPLC method for the simultaneous quanti&amp;amp;ouml;cation of metformin and repaglinide in bulk and tablet dosage forms. Chromatographic separation of the selected drugs was carried out on Phenomenex C18 analytical column (250 mm x 4.6 mm, 5 &amp;amp;mu; particle size). An isocratic elution system was developed using 0.1M ammonium acetate: acetonitrile [50:50 v/v]. The pH of the mobile was adjusted to 4.2 with orthophosphoric acid. The elution of the drugs was achieved with a &amp;amp;oslash;ow rate of 1.0 ml/min. Detection was by UV absorbance at a wavelength of 254 nm. The detector response was linear in the concentration of 500-1500 &amp;amp;micro;g/ml and 2-6 &amp;amp;micro;g/ml for metformin and repaglinide, respectively. The method was validated following ICH guidelines. All the parameters of validation were found in the acceptance range.&amp;lt;/p&amp;gt;</p>
			</abstract>			
			<counts>
				<ref-count count="7"/>
				<page-count count="2"/>
			</counts>
		</article-meta>
	</front>
</article>