Original Research Paper Surgery

International normalized ratio monitoring in post surgical patients with mechanical prosthetic valve: Our experience.

Dr. DHARMENDRA KUMAR SRIVASTAVA Dr. BHUWAN TIWARI Dr. SK VIJAY Dr. SS RAJPUT Dr. LATA KHATNANI Dr.ANURAG RAI Dr. SANDEEP KUMAR GAUTAM RAI

Abstract

<p> <span style="text–align: justify; font–size: 12pt; line–height: 115%; font–family: "Times New Roman", serif; color: rgb(51, 51, 51);">Although the need for oral anticoagulant therapy in patients with mechanical heart–valve prostheses is not in dispute, the optimal intensity of anticoagulation has been a matter of debate and is measured in </span><span style="text–align: justify; font–size: 12pt; line–height: 115%; font–family: "Times New Roman", serif;">International normalized ratio</span><span style="text–align: justify; font–size: 12pt; line–height: 115%; font–family: "Times New Roman", serif;"> (INR) <span style="color:#333333">value. </span></span><span style="text–align: justify; font–size: 12pt; line–height: 115%; font–family: "Times New Roman", serif; color: rgb(55, 55, 55);">We followed 161 patients</span><span style="text–align: justify; font–size: 12pt; line–height: 115%; font–family: "Times New Roman", serif; color: rgb(51, 51, 51);"> with mechanical prosthetic valve on oral anticoagulants</span><span style="text–align: justify; font–size: 12pt; line–height: 115%; font–family: "Times New Roman", serif; color: rgb(55, 55, 55);"> from June 2012 to December 2016</span><span style="text–align: justify; font–size: 12pt; line–height: 115%; font–family: "Times New Roman", serif; color: rgb(51, 51, 51);">.</span><span style="text–align: justify; font–size: 12pt; line–height: 115%; font–family: "Times New Roman", serif;"> We used ATS–Medtronic (77 cases), TTK Chitra Tilting Disc (71 cases) were most common mechanical heart valve implanted at mitral (65.2%), both aortic and mitral (21.72%) and aortic (13%) positions. In our study we also observed that fluctuations in INR monitoring in patients on oral anticoagulants commonly exists either in range or below range in respect to ACCP guidelines at any types and positions of implanted mechanical heart valve. The below range and in range INR value were at mitral (38.38%, 49.49%), at aortic (52.63%, 31.57%), at both aortic and mitral (55.17%, 37.93%) positions respectively. <span style="color:#333333">In our study we found </span>that proper monitoring of INR during follow–up period and protocol based appropriate timely action taken can enable safe long term anticoagulation.</span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:inter–ideograph"><span style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman",serif"><span style="color:#333333"> <o:p></o:p></span></span></p>

Keywords: Valvular heart disease, Oral anticoagulation, mechanical heart–valve, International normalized ratio