Mahendra Swami, Arun Vaishy, Ravi Kumar, Ankit Soni, CLINICAL STUDY ON THE USE OF DYNAMIC COMPRESSION PLATE IN THE MANAGEMENT OF ACUTE DIAPHYSEAL FRACTURES OF THE RADIUS AND ULNA., INDIAN JOURNAL OF APPLIED RESEARCH : Volume‾7 | Issue‾4 | April-2017
<p> <span style="font–size: 11.5pt;">Background and Objectives</span></p>
<p class="Default"><span style="font–size:11.5pt;mso–ansi–language:EN–US">Fractures of the forearm bones may result in severe loss of function unless adequately treated. Severe loss of function may result even though adequate healing of the fractures occurs. To study the principles of dynamic compression plate. To assess the functional outcome of patient with reference to rate of fracture union & its complications. To study follow–up & restoration of function of the forearm</span><span lang="EN–IN" style="font–size:11.5pt"><o:p></o:p></span></p>
<p class="Default"><span style="font–size:11.5pt;mso–ansi–language:EN–US">Methods</span><span lang="EN–IN" style="font–size:11.5pt"><o:p></o:p></span></p>
<p class="Default"><span style="font–size:11.5pt;mso–ansi–language:EN–US">20 patients with acute diaphyseal fractures of the radius and ulna were treated</span><span lang="EN–IN" style="font–size:11.5pt"><o:p></o:p></span></p>
<p class="Default"><span style="font–size:11.5pt;mso–ansi–language:EN–US">with open reduction and internal fixation with dynamic compression plate and screws at</span><span lang="EN–IN" style="font–size:11.5pt"><o:p></o:p></span></p>
<p class="Default"><span style="font–size:11.5pt;mso–ansi–language:EN–US">our centere. The recently developed AOcompression plating apparatus seemed to satisfy the basic objectives of internal fixation ;namely (1) anatomical reduction (2) preservation of vascularity (3) mechanically stablefixation and (4) rapid mobilization of the joints in proximity. The 3.5 mm DCPB gave excellent results in patients who had a fracture of the forearm, and it minimized the risk of refracture.</span><span lang="EN–IN" style="font–size:11.5pt"><o:p></o:p></span></p>
<p class="Default"><span lang="EN–IN" style="font–size:11.5pt">Results<o:p></o:p></span></p>
<p class="Default"><span style="font–size:11.5pt;mso–ansi–language:EN–US">Excellent results were obtained in 60%, good results in 30%, fair and 10% of the</span><span lang="EN–IN" style="font–size:11.5pt"><o:p></o:p></span></p>
<p class="Default"><span style="font–size:11.5pt;mso–ansi–language:EN–US">cases.</span><span lang="EN–IN" style="font–size:11.5pt"><o:p></o:p></span></p>
<p class="Default"><span lang="EN–IN" style="font–size:11.5pt">Conclusion<o:p></o:p></span></p>
<p class="Default"><span style="font–size:11.5pt;mso–ansi–language:EN–US">To conclude, dynamic compression plate is an excellent fixation for displaced</span><span lang="EN–IN" style="font–size:11.5pt"><o:p></o:p></span></p>
<p class="Default"><span style="font–size:11.5pt;mso–ansi–language:EN–US">diaphyseal fractures of the forearm bones. With stable / rigid internal fixation, the</span><span lang="EN–IN" style="font–size:11.5pt"><o:p></o:p></span></p>
<p><span style="font–size:11.5pt;font–family:"Times New Roman",serif;mso–fareast–font–family:
"Arial Unicode MS";mso–ansi–language:EN–US;mso–fareast–language:EN–US;
mso–bidi–language:AR–SA">external immobilization was not required in co–operative patients</span></p>
Keywords: Diaphyses, forearum, fracture, internal fixation, prostheses and implants, fracture fixation, Cross–Sectional Studies, Data Interpretation, Statistical