Dr. Mwahib Aldosh, Safety of MRI technology in different magnetic fields, INDIAN JOURNAL OF APPLIED RESEARCH : Volume‾7 | Issue‾7 | July‾2017
<p> <b style="text–align: justify;"><span style="font–size:14.0pt;line–height:200%;
font–family:"Times New Roman",serif;mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:
major–bidi;mso–bidi–theme–font:major–bidi">Objectives</span></b><span style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">: This study was conducted in order to analyze MRI safety in different magnetic strengths And aimed to fill gap present in current MRI literature, linking the basic theory with clinical practice.</span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:kashida;text–kashida:
10%;line–height:200%"><span style="font–size:14.0pt;mso–bidi–font–size:11.0pt;
line–height:200%;font–family:"Times New Roman",serif;mso–ascii–theme–font:major–bidi;
mso–hansi–theme–font:major–bidi;mso–bidi–theme–font:major–bidi">Material and Methods</span><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman",serif;
mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:major–bidi;mso–bidi–theme–font:
major–bidi">: The present study, is descriptive and practice work to evaluate the safety of MRI examinations and discuss the finding results with similar studies found in literature. The sample group consist of 60 healthy adult ,diagnosed with different types and models of MRI systems in different power strengths commonly used 0.2T, 1.5T and 3T. Technique used is standard protocol for head scan .Others parameters including digital micro electronics devices to measure skin temperature and blood pressure . In addition to observations check list to record signs and symptoms which a beer during or after the MRI exam.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:kashida;text–kashida:
10%;line–height:200%"><span style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman",serif;mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:
major–bidi;mso–bidi–theme–font:major–bidi"> Data were collected from the period of September 2016 to May 2017 and analyzed statically using statistically package for social sciences (SPSS)</span><span style="font–size:16.0pt;line–height:200%"> </span><span style="font–size:12.0pt;
line–height:200%;font–family:"Times New Roman",serif;mso–ascii–theme–font:major–bidi;
mso–hansi–theme–font:major–bidi;mso–bidi–theme–font:major–bidi">program.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:kashida;text–kashida:
10%;line–height:200%"><b><span style="font–size:14.0pt;line–height:200%;
font–family:"Times New Roman",serif;mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:
major–bidi;mso–bidi–theme–font:major–bidi">Results</span></b><b><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman",serif;
mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:major–bidi;mso–bidi–theme–font:
major–bidi">:</span></b><span style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman",serif;mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:
major–bidi;mso–bidi–theme–font:major–bidi"> The results achieved that ,there is an elevation in skin temperature associate with strength field, but not significant that can produce ill effect</span><span style="font–size:10.0pt;line–height:200%;font–family:TrebuchetMS;mso–ascii–font–family:
TrebuchetMS">.</span><span style="font–size:12.0pt;line–height:200%;font–family:
"Times New Roman",serif;mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:
major–bidi;mso–bidi–theme–font:major–bidi"> And regarding biological changes in blood pressure, the data showed a slight increase demonstrated by higher field strengths and it increases by the increase in magnetic field however it’s insignificant</span><span style="font–size:10.0pt;line–height:200%;font–family:TrebuchetMS;mso–ascii–font–family:
TrebuchetMS">. </span><span style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman",serif;mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:
major–bidi;mso–bidi–theme–font:major–bidi">Moreover most symptoms are shown by high field magnets 3T. Whereas the data provides 40% abnormal observations. <o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;text–justify:kashida;text–kashida:
10%;line–height:200%"><b><span style="font–size:14.0pt;line–height:200%;
font–family:"Times New Roman",serif;mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:
major–bidi;mso–bidi–theme–font:major–bidi">Conclusion</span></b><b><span style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman",serif;
mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:major–bidi;mso–bidi–theme–font:
major–bidi">:</span></b><span style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman",serif;mso–ascii–theme–font:major–bidi;mso–hansi–theme–font:
major–bidi;mso–bidi–theme–font:major–bidi"> A recent study concluded that it was very difficult to prove the existence of significant biological effects. And the author thought that, the values obtained in this study are useful were it offer a detailed look at MRI technology, risks and patient safety and ended by recommended for using high filed strength, just according to the need to produce enough signal for an adequate imaging<o:p></o:p></span></p>
Keywords: MRI, imaging, Radiation effects, Safety, clinical Technology