Original Research Paper Orthopaedics

BIOLOGICAL FIXATION OF COMMINUTED SUBTROCHANTERIC FRACTURES USING DYNAMIC HIP SCREW

DR. ANEEN N. KUTTY DR. RAVIKUMAR V

Abstract

<p> <b style="text–align: justify;"><span style="font–family:"Arial Unicode MS",sans–serif">INTRODUCTION</span></b><b style="text–align: justify;"><span style="font–family:"Arial Unicode MS",sans–serif"> – </span></b><span style="text–align: justify; font–family: "Arial Unicode MS", sans–serif;">Comminuted subtrochanteric fractures are the most difficult to manage among femoral fractures because of unique characteristics of proximal femur and as most of the cases are comminuted. Recently, fixation without exploration of the fracture site, known as "biologic fixation”, has been introduced. Eventhough Intramedullary implants are preferred for unstable subtrochanteric fractures we opted bridge plating with Dynamic Hip Screw for such fractures.</span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b><span style="font–family:"Arial Unicode MS",sans–serif">AIM OF THE STUDY</span></b><b><span style="font–family:"Arial Unicode MS",sans–serif"> – </span></b><span style="font–family:"Arial Unicode MS",sans–serif;mso–bidi–font–weight:
bold">To analyse the functional outcome of bridge plating with Dynamic Hip Screw for unstable comminuted subtrochanteric fractures.</span><b><span style="font–family:"Arial Unicode MS",sans–serif"><o:p></o:p></span></b></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b><span style="font–family:"Arial Unicode MS",sans–serif">MATERIALS AND METHODS </span></b><b><span style="font–family:"Arial Unicode MS",sans–serif">– </span></b><span style="font–family:"Arial Unicode MS",sans–serif;mso–bidi–font–weight:
bold">The study included 20 patients with comminuted subtrochanteric fractures of the femur treated by bridge plating with DHS. </span><b><span style="font–family:"Arial Unicode MS",sans–serif"><o:p></o:p></span></b></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b><span style="font–family:"Arial Unicode MS",sans–serif">RESULTS</span></b><b><span style="font–family:"Arial Unicode MS",sans–serif"> – </span></b><span style="font–family:"Arial Unicode MS",sans–serif;mso–bidi–font–weight:
bold">The fractures united at a mean of 7.6 (range, 3–15) months postoperatively. Mobility was scored at 9 points in 18 patients and 6 points in 2 patients (Mobility score of Parker & Palmer).<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b><span style="font–family:"Arial Unicode MS",sans–serif">CONCLUSION – </span></b><span style="font–family:"Arial Unicode MS",sans–serif;mso–bidi–font–weight:bold">The results of this study highly suggest use of bridge plating in the treatment of comminuted subtrochanteric fractures, especially in the third world countries.<b><o:p></o:p></b></span></p>

Keywords: biological fixation, bridge–plating, subtrochanteric fracture, dynamic hip screw, mobility Score