Original Research Paper Ophthalmology

OUTCOME COMPARISON OF TORSIONAL MICROCOAXIAL PHACOEMULSIFICATION USING 30 AND 45 DEGREE APERTURE ANGLE NEEDLE

Dr. Gopesh Bhardwaj Dr. Dhara Mahendra Dr. J. K. Chouhan

Abstract

<p> <span lang="EN–IN" style="text–align: justify; background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial; line–height: 200%; font–family: "Times New Roman", serif;">Aims: </span><span lang="EN–IN" style="text–align: justify; line–height: 200%; font–family: "Times New Roman", serif;">To assess and compare the postoperative outcomes of torsional microcoaxial phacoemulsification surgeries performed using 30 and 45 degree aperture angled needles.</span></p>
<p class="MsoNormal" style="margin–top:12.0pt;margin–right:0in;margin–bottom:
12.0pt;margin–left:0in;text–align:justify;line–height:200%;tab–stops:.5in"><span lang="EN–IN" style="mso–bidi–font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Materials and methods: This randomized, single blinded comparative follow up study was conducted on 80 patients attending Eye OPD diagnosed with uncomplicated senile cataract.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–top:12.0pt;margin–right:0in;margin–bottom:
12.0pt;margin–left:0in;text–align:justify;line–height:200%;tab–stops:.5in"><span lang="EN–IN" style="mso–bidi–font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Result & analysis: Group A (40 eyes of 40 patients) underwent coaxial torsional phacoemulsification using 45 degree aperture angle & Group B (40 eyes of 40 patients) using 30 degree aperture angle. Both the groups were similar in terms of age, sex, cataract grade and the eye which was operated. (P> 0.05 for each of them).We found lower values of CDE and total UST during the surgery in Group A which were <span style="background–image: initial; background–position: initial; background–size: initial; background–repeat: initial; background–attachment: initial; background–origin: initial; background–clip: initial;">statistical significance with P values </span>=0.001</span><span lang="EN–IN" style="line–height: 200%; font–family: "Times New Roman", serif;">0 and 0.027s respectively. Volume of BSS used in group A was high than in group B but the difference was not statistically significant with P values = </span><span lang="EN–IN" style="mso–bidi–font–size:
12.0pt;line–height:200%;font–family:"Times New Roman","serif";mso–fareast–font–family:
"Times New Roman"">0.214.</span><span lang="EN–IN" style="mso–bidi–font–size:
12.0pt;line–height:200%;font–family:"Times New Roman","serif""> Mean Endothelial cell loss was higher in Group B in all postoperative visits of 1 week, 1 month and 3 month but this difference was statistically significant only at 1 week post op with P value 0.04 at 1 week , 0.248 and 0.815 at 1 month and 3 month respectively. We found better values of BCVA in group A than group B but the difference </span><span lang="EN–IN" style="line–height: 200%; font–family: "Times New Roman", serif;">was not statistically significant with P values</span><span lang="EN–IN" style="mso–bidi–font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif""> at 1 week, 1 month , and 3 month were 0.20 , 0.09, 0.546 and 0.058 respectively.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–top:12.0pt;margin–right:0in;margin–bottom:
12.0pt;margin–left:0in;text–align:justify;line–height:200%;tab–stops:.5in"><span lang="EN–IN" style="font–family:"Times New Roman","serif";mso–fareast–font–family:
"Times New Roman"">Conclusion : </span><span lang="EN–IN" style="font–family:
"Times New Roman","serif"">This suggest that phacoemulsification using 45 degree needle may be slightly superior than 30 degree in terms of total energy dissipated in eyes but the final clinical result is not clinically significant or superior.<o:p></o:p></span></p>

Keywords: torsional phacoemulsification, endothelial cell, cataract