Dr Sumit Goyal, Dr Shikha Dhal, Dr U Suryanarayana, Dr Pooja Nandwani Patel, Dr R.K Vyas, ASSESSMENT OF PTV MARGIN IN HEAD AND NECK CANCER: AN INSTITUTIONAL STUDY., INDIAN JOURNAL OF APPLIED RESEARCH : Volume-7 | Issue-11 | November-2017
<p> <b><span style="font–size:14.0pt;line–height:200%;font–family:"Times New Roman","serif"">Introduction:</span></b><span style="font–size: 14pt; line–height: 200%; font–family: "Times New Roman", serif;">Head and neck cancer radiotherapy usually delivered using IMRT (Intensity Modulated Radiotherapy) technique.</span><span style="font–size: 14pt; line–height: 200%; font–family: "Times New Roman", serif;">EPID (Electronic Portal Imaging Device) and CBCT (Cone Beam Computed Tomography) scan helps in determining systemic and the random positioning deviations for a setup,which may be the base for establishing the specific correction protocol in order to improve setup techniques.</span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b><span style="font–size:14.0pt;mso–bidi–font–size:
16.0pt;line–height:200%;font–family:"Times New Roman","serif";mso–bidi–font–family:
Shruti;mso–bidi–theme–font:minor–bidi">Aims and Objectives:</span></b><span style="font–size:14.0pt;mso–bidi–font–size:16.0pt;line–height:200%;font–family:
"Times New Roman","serif";mso–bidi–font–family:Shruti;mso–bidi–theme–font:minor–bidi">Aim of this retrospective analysis was to assess PTV margin of our institute in head and neck cancer treated using IMRT.<b><o:p></o:p></b></span></p>
<p class="MsoNormal" style="text–align:justify;line–height:200%"><b><span style="font–size:14.0pt;mso–bidi–font–size:
16.0pt;line–height:200%;font–family:"Times New Roman","serif";mso–bidi–font–family:
Shruti;mso–bidi–theme–font:minor–bidi">Material and Methods</span></b><span style="font–size:14.0pt;mso–bidi–font–size:16.0pt;line–height:200%;font–family:
"Times New Roman","serif";mso–bidi–font–family:Shruti;mso–bidi–theme–font:minor–bidi">:We have retrospectively assessed seventy head and neck cancer patient who has received IMRT and image verification done using CBCT from June 2016 to December 2016 for the assessment of PTV margin of our institute. Shifts along X–axis, Y axis and Z–axis obtained by matching with reference image was noted.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><b><span style="font–size:14.0pt;mso–bidi–font–size:16.0pt;line–height:
200%;font–family:"Times New Roman","serif"">RESULTS:</span></b><span style="font–size:14.0pt;mso–bidi–font–size:16.0pt;line–height:200%;font–family:
"Times New Roman","serif"">Out of seventy patients eleven (11/70) were female and rest all (59/70) were male patients. Total 367 CBCT were taken among seventy patients.<b><o:p></o:p></b></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:14.0pt;
mso–bidi–font–size:16.0pt;line–height:200%;font–family:"Times New Roman","serif"">Systemic Errors (SE) were 0.18, 0.15 and 0.15 cm along X–axis, Y–axis and Z–axis respectively. Random Errors (RE) were 0.13, 0.12 and 0.12 cm along X–axis, Y–axis and Z–axis respectively. <o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><span style="font–size:14.0pt;
mso–bidi–font–size:16.0pt;line–height:200%;font–family:"Times New Roman","serif"">PTV margin calculated using Van Herk’s margin recipe (2.5SE+0.7RE) were 0.541, 0.466 and 0.459 cm along X–axis, Y–axis and Z–axis respectively. The empirical PTV margin given was 5mm and from our study also it was within 5mm.<o:p></o:p></span></p>
<p class="MsoNormal" style="line–height:200%"><b><span style="font–size:14.0pt;mso–bidi–font–size:16.0pt;line–height:
200%;font–family:"Times New Roman","serif"">CONCLUSION:</span></b><span style="font–size:14.0pt;mso–bidi–font–size:16.0pt;line–height:200%;font–family:
"Times New Roman","serif""> PTV margin obtained were comparative to different studies done all over world and now further trying to reduce it to 3mm by doing daily onboard imaging.<o:p></o:p></span></p>