MS RENITA NORONHA, MRS VICTORIA D¥ALMEIDA, MS BRIGIT A P (SR DEEPA PETER), EFFECT OF A CONTINUOUS CARE MODEL (CCM) ON SLEEP QUALITY AMONG PATIENTS WITH TYPE 2 DIABETES MELLITUS IN A SELECTED HOSPITAL AT MANGALURU, INDIAN JOURNAL OF APPLIED RESEARCH : Volume-7 | Issue-11 | November-2017
<p> <span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">A Quasi–Experimental pre test–post test control group design </span><span style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">was used to determine the effect of a CCM on sleep quality</span><b style="text–align: justify;"><span style="font–size:12.0pt;line–height:
200%;font–family:"Times New Roman","serif";mso–fareast–font–family:"Times New Roman";
mso–ansi–language:EN–IN;mso–fareast–language:EN–IN"> </span></b><span style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">among 60 patients with Type 2 DM. </span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">The aim of the study was to assess the effect of a CCM on the sleep quality among patients with type 2 DM</span><span style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;"> in the experimental and control group. </span><span style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">The investigator </span><span style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">administered the tool to the participants using Baseline Proforma and Pittsburgh Sleep Quality Index. </span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">The screening for low sleep quality wa</span><span style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">s done on 70 type 2 </span><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 200%; font–family: "Times New Roman", serif;">DM patients. The paired ‘t’ value (<b>t<sub>29=</sub></b>12.5, p<0.05) showed that there is a significant difference between the pre and post interventional sleep quality among the type 2DM patients in the experimental group. The Unpaired ‘t’ value (<b>t<sub>58 =</sub></b>2.00, p<0.05) showed that there is a significant difference in mean post interventional quality of sleep score in the experimental and control group. The study showed that there was significant increase in the sleep quality of type 2 DM patients after administrating CCM.</span></p>
<p class="MsoNormal" style="margin–top:0in;margin–right:0in;margin–bottom:6.0pt;
margin–left:–4.5pt;text–align:justify;line–height:200%;tab–stops:0in .5in"><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–fareast–font–family:"Times New Roman";mso–ansi–language:EN–IN;mso–fareast–language:
EN–IN"><o:p></o:p></span></p>
Keywords: Sleep quality, Type 2 DM Patients, Effect, CCM