Original Research Paper Urology

INNOVATIVE METAL DILATORS FOR NEPHROSTOMY TRACT

Dr. A. K. Sanwal Dr. Sanjay Chaube Dr. Jyoti Chaube

Abstract

<p> <b style="text–align: justify;"><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;">Background: </span></b><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 115%;">Dilators</span><b style="text–align: justify;"><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;"> </span></b><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 115%;">nephrostomy have<b> </b></span><b style="text–align: justify;"><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;"> </span></b><span lang="EN–IN" style="text–align: justify; font–size: 12pt; line–height: 115%;">an </span><span style="text–align: justify; font–size: 12pt; line–height: 115%;">important component role in percutaneous renal access. Metal telescopic dilators are reusable and economical. They maintain a tamponade effect throughout the dilatation.</span></p>
<div style="mso–element:para–border–div;border:solid windowtext 1.0pt;
mso–border–alt:solid windowtext .5pt;padding:1.0pt 4.0pt 1.0pt 4.0pt">
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;text–justify:inter–ideograph;mso–layout–grid–align:none;text–autospace:
none;border:none;mso–border–alt:solid windowtext .5pt;padding:0in;mso–padding–alt:
1.0pt 4.0pt 1.0pt 4.0pt"><b><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;">Aims and objective:</span></b><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;"> </span><span style="font–size: 12pt; line–height: 115%;">The objective for this article is to compare the new dilator which has been prepared by Dr. A. K. Sanwal.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;text–justify:inter–ideograph;border:none;mso–border–alt:solid windowtext .5pt;
padding:0in;mso–padding–alt:1.0pt 4.0pt 1.0pt 4.0pt"><b><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;">Materials and Methods:</span></b><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;"> </span><span style="font–size: 12pt; line–height: 115%;">“Sanwal Dilator” was used in approximately 400 consecutive cases of PCNL from January 2012 till January 2017.</span><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;"><o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;text–justify:inter–ideograph;border:none;mso–border–alt:solid windowtext .5pt;
padding:0in;mso–padding–alt:1.0pt 4.0pt 1.0pt 4.0pt"><b><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;">Results: </span></b><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;">“Sanwal dilator” is metallic type of dilator. In comparison of Alkem, fascial or scrue dilators, “Sanwal dilator” is </span><span style="font–size: 12pt; line–height: 115%;">very fast for </span><span lang="EN–IN" style="font–size: 12pt; line–height: 115%;">the procedure of dilation, telescopic thus less bleeding, applicable in all types of PCNL, in redo cases, long lasting, can be used for years, low cost and made in India.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;text–justify:inter–ideograph;border:none;mso–border–alt:solid windowtext .5pt;
padding:0in;mso–padding–alt:1.0pt 4.0pt 1.0pt 4.0pt"><b><span style="font–size: 12pt; line–height: 115%;">Conclusion:</span></b><span style="font–size: 12pt; line–height: 115%;"> “Sanwal Dilator” is a safe and good alternative for other metal telescopic dilators available in the market. <o:p></o:p></span></p>
</div>

Keywords: : Dilator, Percutaneous Nephrolithotomy