Original Research Paper Surgery

Prospective Study To Establish Correlation Between Maximum Rise In Rectal Temperature And Minimum Effective Power For Vapourization During TUEVP In BPH And Its Effect On Post Operative Results

Shivam Singh Kartik Saxena Nishi Gupta Desai Sandipkumar Vallabhbhai Shekhar Shivam Rijul Saini Gourav S. Makkar

Abstract

<p> </p>
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="mso–bidi–font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">BACKGROUND<o:p></o:p></span></b></p>
<p class="MsoNormal" style="text–indent:28.35pt"><span lang="EN–IN" style="mso–bidi–font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Out of the Various Surgical Management Techniques For Benign Prostatic Hyperplasia, Transurethral Electrovapourization of Prostate is a Minimal invasive procedure comparable to Transurethral Resection of Prostate which removes prostatic tissue by using High Vapourization Power , combining the effects of Vapourization and Dessication. <o:p></o:p></span></p>
<p class="MsoNormal" style="text–indent:28.35pt"><span lang="EN–IN" style="mso–bidi–font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">The Study Aims to Establish the Co–relation between the Maximum Rise in Rectal Temperature and Minimum Effective Power for Vapourization used during TUEVP and its Effect on Post Operative Results, thus helping us to have an idea about the effect of lateral thermal damage at high energy levels during TUEVP.<o:p></o:p></span></p>
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="mso–bidi–font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">METHODS<o:p></o:p></span></b></p>
<p class="MsoNormal" style="text–indent:28.35pt"><span lang="EN–IN" style="mso–bidi–font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">The Prospective Study was Conducted on 60 Patients of Benign Prostatic Hyperplasia at SGMH, New Delhi. Continous Rectal temperature monitoring was done during TUEVP and Maximum Rise in Rectal temperature was noted at different Vapourization Powers. Patients post operative results<span style="mso–spacerun:yes"> </span>were assessed<span style="mso–spacerun:yes"> </span>on basis of IPSS and QOL index and complications<span style="mso–spacerun:yes"> </span>if any were noted with a follow up of 3 months . Results were compared with the Vapourization power (150–300 Watt) used along with Maximum Rise in Rectal Temperature.<o:p></o:p></span></p>
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="mso–bidi–font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">RESULTS<o:p></o:p></span></b></p>
<p class="MsoNormal" style="text–indent:28.35pt"><span style="mso–bidi–font–size:
12.0pt;line–height:115%;font–family:"Times New Roman","serif";mso–ansi–language:
EN–US">The Mean of Maximum Rise in Rectal Temperature was .5<sup>o </sup>C at 160 MEPV, 1.005<sup>o</sup>C at 180 MEPV, .4<sup>o</sup>C at 190 MEPV and 1.52<sup>o</sup>C at 200 MEPV. At MEPV of 220 , 240 ,260 and 280 Watts,<span style="mso–spacerun:yes"> </span>the Mean of Maximum Rise in Rectal Temperature was<span style="mso–spacerun:yes"> </span>2.2<sup>o </sup>, 2.4<sup>o</sup> , 2.55<sup>o </sup>and<span style="mso–spacerun:yes"> </span>2.8<sup>o</sup> Celsius , respectively.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–indent:28.35pt"><span style="mso–bidi–font–size:
12.0pt;line–height:115%;font–family:"Times New Roman","serif";mso–ansi–language:
EN–US">At 160 MEPV, there was no complications. <span style="mso–spacerun:yes"> </span>At 180 MEPV, 96.87% had no complications while 3.12% of patients had Clot retention. At 190 and 200 MEPV, there were no complications. At 220 MEPV, 25% patients had Clot retention. At 240 MEPV 66.67% had no complications while 33.33% of patients had Clot Retention. At 260 MEPV<span style="mso–spacerun:yes"> </span>, 50%<span style="mso–spacerun:yes"> </span>of<span style="mso–spacerun:yes"> </span>patients<span style="mso–spacerun:yes"> </span>had<span style="mso–spacerun:yes"> </span>Retrograde ejaculation .At 280 MEPV only 1 patient was operated<span style="mso–spacerun:yes"> </span>which developed Clot retention (100%).<o:p></o:p></span></p>
<p class="MsoNormal"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="mso–bidi–font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">CONCLUSION<o:p></o:p></span></b></p>
<p class="MsoNormal" style="text–indent:28.35pt"><span style="mso–bidi–font–size:
12.0pt;line–height:115%;font–family:"Times New Roman","serif";mso–ansi–language:
EN–US">This study had established that there was a significant direct correlation between Minimum Effective Power for Vapourization and Rectal Temperature During TUEVP and no siginificant difference in IPSS improvement, QOL improvement and Complications rate.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–indent:28.35pt"><span style="mso–bidi–font–size:
12.0pt;line–height:115%;font–family:"Times New Roman","serif";mso–ansi–language:
EN–US">It showed that at all MEPV Levels , TUEVP was equally efficacious and safe. Only very minor complications occurred which mostly could be tackled immediately.<o:p></o:p></span></p>

Keywords: Transurethral Electrovapourization of Prostate, Benign Prostatic Hyperplasia, Rectal Temperature, Minimum Effective Power for Vapourization(MEPV)