Original Research Paper Radiology

HOW EFFICIENT ARE THE LEAD APRONS USED FOR RADIATION PROTECTION IN OUR HOSPITALS?

CHIEGWU Hyacienth Uche UGWUANYI Daniel Chimuanya OKEJI Mark C ONWUGALU Ebube

Abstract

<p> </p>
<p class="MsoNormal" style="text–align:justify"><b style="mso–bidi–font–weight:
normal"><span style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Background of the study</span></b><span style="font–size:12.0pt;line–height:115%;
font–family:"Times New Roman","serif"">: X–rays are useful in medical care but careless uses of x–rays are harmful. <span style="mso–spacerun:yes"> </span><span style="mso–spacerun:yes"> </span>One<span style="mso–spacerun:yes"> </span>method of<span style="mso–spacerun:yes"> </span>radiation protection is the use of structurally intact <span style="mso–spacerun:yes"> </span>lead apron gowns.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify"><b style="mso–bidi–font–weight:
normal"><span style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Purpose of the study: </span></b><span style="font–size:12.0pt;line–height:115%;
font–family:"Times New Roman","serif"">This study aimed at evaluating the protective efficiency of the lead aprons<span style="mso–spacerun:yes"> </span>used at the radiology department of a tertiary health institution in Anambra State of Nigeria.and <span style="mso–spacerun:yes"> </span>correlate the transmittance, absorbed dose and <span style="mso–spacerun:yes"> </span>transmission efficiency of the aprons with<span style="mso–spacerun:yes"> </span>KVps.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify"><b style="mso–bidi–font–weight:
normal"><span style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Materials and Method: </span></b><span style="font–size:12.0pt;line–height:115%;
font–family:"Times New Roman","serif"">Nine (9) protective lead aprons of different type/make, lead equivalent and length of use were evaluated. Fluoroscopy and conventional x–rays were used. A pile of plastic foam was used to simulate a patient. Exposures were made using different KVp, mAs, focus Film distance settings. The lead apron being tested was hung close to the x–ray couch in a position that would be taken by a patient’s relation aiding in the x–ray investigation. A dosimeter placed at a height above the x–ray couch (in front and back of the apron in turn) was used to measure the quantity of scattered radiation incident on the apron and the quantity transmitted through the aprons respectively. The efficiency of the aprons was calculated as the ratio of transmitted beam intensity to the incident beam intensity. Data was analyzed using the Statistical Package for Social Sciences (SPSS) version 20.0. Statistical significance was considered at p < 0.05.<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify"><b style="mso–bidi–font–weight:
normal"><span style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Results:</span></b><span style="font–size:14.0pt;line–height:115%;font–family:"Times New Roman","serif""> </span><span style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Physical examination showed</span><span style="font–size:14.0pt;line–height:115%;
font–family:"Times New Roman","serif""> </span><span style="font–size:12.0pt;
line–height:115%;font–family:"Times New Roman","serif"">that 7 (77.78%) of the aprons were good but qualitative assessment showed that only 4(44.4%) of the lead aprons were in good condition. The efficiency of lead aprons increases with the KVp and decreases with lead thickness<o:p></o:p></span></p>
<p class="MsoNormal" style="text–align:justify"><b style="mso–bidi–font–weight:
normal"><span style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Conclusion: </span></b><span style="font–size:12.0pt;line–height:115%;font–family:"Times New Roman","serif"">Physical examination and qualitative assessment are <span style="mso–spacerun:yes"> </span><span style="mso–spacerun:yes"> </span>important for evaluation of lead aprons. Radiology departments should ensure that lead <span style="mso–spacerun:yes"> </span>suitable are used.for KVp settings on their x–ray equipments. <o:p></o:p></span></p>

Keywords: Lead–aprons, radiation protection, transmission, efficiency