Original Research Paper Medicine

Comparison of HIV fourth generation rapid test with HIV fourth generation ELISA for screening voluntary blood donors.

Dr Satish Kumar Dr Rajat Jagani Dr Amit Pawar Dr Ujjwal Dimri

Abstract

<p> </p>
<p class="MsoNormal" style="margin–left:1.75pt;line–height:200%"><span style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif"">Fourth–generation assays permit the simultaneous detection of HIV antigen and antibody. With this test, it is possible to detect HIV p24 antigen during the window period, if the blood donor happens to be tested during the short peak of high levels of circulating virus particles.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–left:1.75pt;line–height:200%"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:
200%;font–family:"Arial","sans–serif";mso–fareast–font–family:Arial">Material and Methods<o:p></o:p></span></b></p>
<p class="MsoNormal" style="margin–left:1.75pt;line–height:200%"><span style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif";
mso–fareast–font–family:Calibri">In this prospective study, we screened a total of 1599 blood donors which included both whole blood donors and apheresis donors. All samples were screened with 4th generation ELISA (</span><span style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif"">RFCL Limited)</span><span style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif";
mso–fareast–font–family:Calibri">, 4th generation Rapid Immunochromatograpy test (TRI–DOT+Ag, </span><span style="font–size:12.0pt;line–height:200%;
font–family:"Arial","sans–serif"">J. Mitra. & Co. Pvt. Ltd)</span><span style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif";
mso–fareast–font–family:Calibri"> and real time PCR technique. <o:p></o:p></span></p>
<p class="MsoNormal" style="margin–left:1.75pt;line–height:200%"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:
200%;font–family:"Arial","sans–serif";mso–fareast–font–family:Arial">Result and Discussion<o:p></o:p></span></b></p>
<p class="MsoNormal" style="margin–top:.65pt;margin–right:0in;margin–bottom:10.0pt;
margin–left:4.25pt;text–align:justify;text–indent:31.75pt;line–height:200%"><span style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif"">In this study, four positive samples were detected by 4<sup>th</sup> generation ELISA, out of which two samples showed marginal positivity. All four samples were negative by 4<sup>th</sup> generation Rapid TRI–DOT +Ag, but positive with Real Time Polymerase Chain Reaction (RT–PCR) thereby implying a sensitivity of 4<sup>th</sup> gen ELISA comparable to RT–PCR, whereas sensitivity of 4<sup>th</sup> gen Rapid TRI–DOT was greatly inferior to both 4<sup>th</sup> gen ELISA and RT–PCR because of the inherent inability of the 4<sup>th</sup> gen RAPID to pick up cases of low antigenemia and low antibody titer</span><span style="font–size:
12.0pt;line–height:200%;font–family:"Arial","sans–serif";mso–fareast–font–family:
Arial"><o:p></o:p></span></p>
<p class="MsoNormal" style="margin–top:.65pt;margin–right:0in;margin–bottom:10.0pt;
margin–left:4.25pt;text–align:justify;text–indent:31.75pt;line–height:200%"><span style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif";
mso–fareast–font–family:Arial"><o:p> </o:p></span></p>
<p class="MsoNormal" style="margin–left:1.75pt;line–height:200%"><b style="mso–bidi–font–weight:normal"><span style="font–size:12.0pt;line–height:
200%;font–family:"Arial","sans–serif";mso–fareast–font–family:Arial">Conclusion<o:p></o:p></span></b></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;text–indent:.5in;line–height:200%;mso–layout–grid–align:none;
text–autospace:none"><span style="font–size:12.0pt;line–height:200%;font–family:
"Arial","sans–serif";mso–fareast–font–family:Calibri">4<sup>th</sup> generation ELISA should be continued for blood donor screening and rapid TRI–DOT should not be used as an alternative to 4<sup>th</sup> generation ELISA. For a resource poor developing country like India, till the country is able to implement NAT/PCR, 4<sup>th</sup> generation ELISA is a cost effective method for blood donor screening.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;text–align:
justify;line–height:200%;mso–layout–grid–align:none;text–autospace:none"><b><span style="font–size:12.0pt;line–height:200%;font–family:"Arial","sans–serif""><o:p> </o:p></span></b></p>