Dr Shabana S, Dr N Pradeepa, Effect of Preanalytical factors on Variation in Glucose Levels, INDIAN JOURNAL OF APPLIED RESEARCH : Volume-8 | Issue-3 | March-2018
<p> </p>
<p class="MsoNormal" style="line–height:200%"><b style="mso–bidi–font–weight:
normal"><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:
"Times New Roman","serif"">Introduction:</span></b><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif""> <o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
200%"><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:
"Times New Roman","serif"">Variability in the method of collection affects not only the diagnosis of diabetes mellitus but also monitoring of glucose concentration during treatment of diabetes. This study determines the effect of delay in centrifugation of samples on glucose levels and the <span style="mso–spacerun:yes"> </span>stability of<span style="mso–spacerun:yes"> </span>plasma and serum glucose over time.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
200%"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:
12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Material and Methods<span style="color:black"><o:p></o:p></span></span></b></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
200%;mso–layout–grid–align:none;text–autospace:none"><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
mso–fareast–font–family:MinionPro–Regular–Identity–H">This study compared the </span><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif";
color:black">glucose concentrations </span><span lang="EN–IN" style="font–size:
12.0pt;line–height:200%;font–family:"Times New Roman","serif";mso–fareast–font–family:
MinionPro–Regular–Identity–H">by two different collection methods. Blood samples</span><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;
font–family:"Times New Roman","serif";color:black"> were collected in either </span><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:"Times New Roman","serif"">non –vacuum<span style="color:black"> NaF or heparin tubes in one method and in the second method in either clot activator or serum separator tubes. </span><o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
200%"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:
12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Results<o:p></o:p></span></b></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
200%"><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:
"Times New Roman","serif"">The levels of glucose as well as stability of the sample was higher in plasma than serum. Plasma glucose of NaF tubes and serum glucose of <span style="color:black">serum separator tubes</span> was higher and more stable than plasma glucose of heparin and<span style="mso–spacerun:yes"> </span>serum glucose of clot activator tubes.<o:p></o:p></span></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
200%"><b style="mso–bidi–font–weight:normal"><span lang="EN–IN" style="font–size:
12.0pt;line–height:200%;font–family:"Times New Roman","serif"">Conclusion<o:p></o:p></span></b></p>
<p class="MsoNormal" style="margin–bottom:0in;margin–bottom:.0001pt;line–height:
200%"><span lang="EN–IN" style="font–size:12.0pt;line–height:200%;font–family:
"Times New Roman","serif"">Samples collected for estimation of glucose should be separated as soon as possible. Monitoring of glucose concentrations should be done by the same collection method.<o:p></o:p></span></p>
Keywords: Glucose, Serum, Plasma