Dr Pujitha Murthi, Dr Shipra Sonkusare, TALE OF MISSING COPPER T DEVICE AND SUCCESSFUL RETRIEVAL, INDIAN JOURNAL OF APPLIED RESEARCH : Volume-8 | Issue-4 | April-2018
<p> Intrauterine devices are currently one of the most popular reversible contraception methods used worldwide. IUCD is</p>
<div>common method of contraception among women because of its low cost and high efficacy. Though relatively safe, it may</div>
<div>cause dangerous complications like uterine perforation. Perforation of the uterus by an IUCD was first described in 1930 by Murphy and Andrews</div>
<div>independently. The incidence of perforation is 0.1 to 3 per 1000 insertions. Uterine perforation almost always occurs during insertion of IUCD</div>
<div>and its incidence is related to the timing of insertion, type of device, the anatomy of the uterus and cervix, also faulty insertion technique, soft</div>
<div>uterine wall, recent pregnancy, abortion and previous uterine scar. With this , we are presenting a case of 25yr old, with complaints of pain</div>
<div>abdomen since 3 days. She was P1L1 delivered by LSCS 3 months back, IUCD insertion was done 6 weeks following the delivery. Her general</div>
<div>physical examination and systemic examination were within normal limits. On per speculum examination, IUCD thread was not seen. X–ray of</div>
<div>the pelvis was done and showed the Copper T to be anterior to the uterus. Laproscopy revealed adhesions between the omentum and anterior</div>
<div>abdominal wall, following successful adhesiolysis the copper T was retrieved</div>